PURPOSE: To study the correlation between apparent diffusion coefficient (ADC) and pathology in patients with undefined breast lesion, to validate how accurately ADC is related to histology, and to define a threshold value of ADC to distinguish malignant from benign lesions. MATERIALS AND METHODS: Seventy-eight patients (110 lesions) were referred for positive or dubious findings. Three-dimensional fast low-angle shot (3D-FLASH) with contrast injection was applied. EPI diffusion-weighted imaging (DWI) with fat saturation was performed, and ROIs were selected on subtraction 3D-FLASH images before and after contrast injection, and copied on an ADC map. Inter- and intraobserver analyses were performed. RESULTS: At pathology 22 lesions were benign, 65 were malignant, and 23 were excluded. The ADCs of malignant and benign lesions were statistically different. In malignant tumors the ADC was (mean +/- SEM) 0.95 +/- 0.027 x 10(-3)mm(2)/second, and in benign tumors it was 1.51 +/- 0.068 x 10(-3)mm(2)/second. According to receiver operating characteristic (ROC) curves, we found a threshold between malignant and benign lesions for highest sensitivity and specificity (both 86%) around 1.13 +/- 0.10 x 10(-3)mm(2)/second. For a threshold of 0.95 +/- 0.10 x 10(-3)mm(2)/second, specificity was 100% but sensitivity was very low. Inter- and intraobserver studies showed good reproducibility. CONCLUSION: The ADC may help to differentiate benign and malignant lesions with good specificity, and may increase the overall specificity of breast MRI.
PURPOSE: To study the correlation between apparent diffusion coefficient (ADC) and pathology in patients with undefined breast lesion, to validate how accurately ADC is related to histology, and to define a threshold value of ADC to distinguish malignant from benign lesions. MATERIALS AND METHODS: Seventy-eight patients (110 lesions) were referred for positive or dubious findings. Three-dimensional fast low-angle shot (3D-FLASH) with contrast injection was applied. EPI diffusion-weighted imaging (DWI) with fat saturation was performed, and ROIs were selected on subtraction 3D-FLASH images before and after contrast injection, and copied on an ADC map. Inter- and intraobserver analyses were performed. RESULTS: At pathology 22 lesions were benign, 65 were malignant, and 23 were excluded. The ADCs of malignant and benign lesions were statistically different. In malignant tumors the ADC was (mean +/- SEM) 0.95 +/- 0.027 x 10(-3)mm(2)/second, and in benign tumors it was 1.51 +/- 0.068 x 10(-3)mm(2)/second. According to receiver operating characteristic (ROC) curves, we found a threshold between malignant and benign lesions for highest sensitivity and specificity (both 86%) around 1.13 +/- 0.10 x 10(-3)mm(2)/second. For a threshold of 0.95 +/- 0.10 x 10(-3)mm(2)/second, specificity was 100% but sensitivity was very low. Inter- and intraobserver studies showed good reproducibility. CONCLUSION: The ADC may help to differentiate benign and malignant lesions with good specificity, and may increase the overall specificity of breast MRI.
Authors: Pascal A T Baltzer; Anja Schäfer; Matthias Dietzel; David Grässel; Mieczyslaw Gajda; Oumar Camara; Werner A Kaiser Journal: Eur Radiol Date: 2010-07-29 Impact factor: 5.315
Authors: Sana Parsian; Habib Rahbar; Kimberly H Allison; Wendy B Demartini; Matthew L Olson; Constance D Lehman; Savannah C Partridge Journal: Radiology Date: 2012-10-02 Impact factor: 11.105
Authors: Dorota J Wisner; Nathan Rogers; Vibhas S Deshpande; David N Newitt; Gerhard A Laub; David A Porter; John Kornak; Bonnie N Joe; Nola M Hylton Journal: J Magn Reson Imaging Date: 2013-11-08 Impact factor: 4.813
Authors: Maarten W Barentsz; Valentina Taviani; Jung M Chang; Debra M Ikeda; Kanae K Miyake; Suchandrima Banerjee; Maurice A A J van den Bosch; Brian A Hargreaves; Bruce L Daniel Journal: J Magn Reson Imaging Date: 2015-04-24 Impact factor: 4.813