Literature DB >> 16782643

Computer-assisted analysis of lower limb geometry: higher intraobserver reliability compared to conventional method.

S Hankemeier1, T Gosling, M Richter, T Hufner, C Hochhausen, C Krettek.   

Abstract

Exact radiographic evaluation of lower limb alignment, joint orientation and leg length is crucial for preoperative planning and successful treatment of deformities, fractures and osteoarthritis. Improvement of the accuracy of radiographic measurements is highly desirable. To determine the intraobserver reliability of conventional analysis of lower extremity geometry, 59 long leg radiographs were randomly analyzed 5 times by a single surgeon. The measurements revealed a standard deviation between 0.36 degrees and 1.17 degrees for the angles mLPFA, mLDFA, MPTA, LDTA, JLCA and AMA (nomenclature according to Paley), and 0.94 mm and 0.90 mm for the MAD and leg length, respectively. Computer-assisted analysis with a special software significantly reduced the standard deviation of the mLDFA, MPTA, LDTA, JLCA (each p < 0.001), AMA (p = 0.032) and MAD (p = 0.023) by 0.05-0.36 degrees and 0.14 mm, respectively. Measuring time was reduced by 44% to 6:34 +/- 0:45 min (p < 0.001). Digital calibration by the software revealed an average magnification of conventional long leg radiographs of 4.6 +/- 1.8% (range: 2.7-11.9%). Computer-assisted analysis increases the intraobserver reliability and reduces the time needed for the analysis. Another major benefit is the ease of storage and transfer of digitized images. Due to the varying magnification factors on long leg radiographs, the use of magnification markers for calibration is recommended.

Entities:  

Mesh:

Year:  2006        PMID: 16782643     DOI: 10.3109/10929080600628985

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  28 in total

1.  Gradual correction of idiopathic genu varum deformity using the Ilizarov technique.

Authors:  Young Eun Park; Sang Heon Song; Hyeok Nam Kwon; Mohamed Ahmed Refai; Kwang Won Park; Hae Ryong Song
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-04       Impact factor: 4.342

2.  Digital planning of high tibial osteotomy. Interrater reliability by using two different software.

Authors:  Steffen Schröter; Christoph Ihle; Johannes Mueller; Philipp Lobenhoffer; Ulrich Stöckle; Ronald van Heerwaarden
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-07       Impact factor: 4.342

3.  Upright MRI measurement of mechanical axis and frontal plane alignment as a new technique: a comparative study with weight bearing full length radiographs.

Authors:  Emmanouil Liodakis; Mohamed Kenawey; Iosifina Doxastaki; Christian Krettek; Carl Haasper; Stefan Hankemeier
Journal:  Skeletal Radiol       Date:  2010-12-18       Impact factor: 2.199

4.  Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy.

Authors:  James Moore; Lydia Mychaltchouk; Frédéric Lavoie
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-02       Impact factor: 4.342

5.  Open wedge tibial osteotomies influence on axial rotation and tibial slope.

Authors:  D Kendoff; D Lo; P Goleski; B Warkentine; P F O'Loughlin; A D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-06-07       Impact factor: 4.342

6.  Geometry of the clavicle and reliability of measurement using PACS.

Authors:  Taweechok Wisanuyotin; Chanchai Tidchom; Kowit Chaisiwamonkhol; Prathana Chowchuen; Permsak Paholpak; Winai Sirichativapee; Weerachai Kosuwan; Polasak Jeeravipoolvarn
Journal:  Surg Radiol Anat       Date:  2013-10-29       Impact factor: 1.246

7.  Accuracy of high tibial osteotomy: comparison between open- and closed-wedge technique.

Authors:  S Hankemeier; P Mommsen; C Krettek; M Jagodzinski; J Brand; C Meyer; R Meller
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-12-24       Impact factor: 4.342

8.  Reliability of lower extremity alignment measurement using radiographs and PACS.

Authors:  R G Marx; P Grimm; K A Lillemoe; C M Robertson; O R Ayeni; S Lyman; E A Bogner; H Pavlov
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-03-23       Impact factor: 4.342

9.  Inter-observer variability and its correlation to experience in measurement of lower limb mechanical axis on long leg radiographs.

Authors:  Raju Vaishya; Vipul Vijay; Vikas P Birla; Amit Kumar Agarwal
Journal:  J Clin Orthop Trauma       Date:  2016-06-11

10.  Radiographic Evaluation of Alignment Following Total Knee Arthroplasty - a Systematic Review. Part II.

Authors:  Bogdan Stefan Cretu; Calin Dragosloveanu; Serban Dragosloveanu; Stefan Cristea
Journal:  Maedica (Buchar)       Date:  2018-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.