Literature DB >> 16778622

Multi-detector CT of the chest: influence of dose onto quantitative evaluation of severe emphysema: a simulation study.

Julia Zaporozhan1, Sebastian Ley, Oliver Weinheimer, Ralf Eberhardt, Ioannis Tsakiris, Yasuhiro Noshi, Felix Herth, Hans-Ulrich Kauczor.   

Abstract

PURPOSE: Quantitative evaluation of the lung parenchyma might be impaired or unreliable by use of reduced-dose CT protocols. Aim of the study was to define the threshold where reduced dose has significant impact on quantitative emphysema parameters.
MATERIALS AND METHODS: Thirty patients with severe centrilobular emphysema underwent multidetector computed tomography (120 kV, 150 mAs). Original CT raw data were simulated using 10 mAs settings (10-100 SIMmAs). Quantitative analysis provided lung volume, emphysema volume, emphysema index, mean lung density, and 4 emphysema volume classes. Simulated low-dose results were compared with original acquisition.
RESULTS: Emphysema index showed no clinical relevant variation down to 30 SIMmAs. The large emphysema volume class was significantly different below 50 SIMmAs. The intermediate and small classes showed an overproportional variation below 50 SIMmAs.
CONCLUSIONS: Dose reduction down to 30 SIMmAs is possible for clinical routine. Settings below 50 SIMmAs significantly alter the in-detailed 3-dimensional emphysema quantification.

Entities:  

Mesh:

Year:  2006        PMID: 16778622     DOI: 10.1097/00004728-200605000-00018

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  20 in total

1.  Extrapolation from ten sections can make CT-based quantification of lung aeration more practicable.

Authors:  A W Reske; A P Reske; H A Gast; M Seiwerts; A Beda; U Gottschaldt; C Josten; D Schreiter; N Heller; H Wrigge; M B Amato
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

Review 2.  Morphological and functional imaging in COPD with CT and MRI: present and future.

Authors:  Julia Ley-Zaporozhan; Sebastian Ley; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2007-09-27       Impact factor: 5.315

3.  Whole-lung densitometry versus visual assessment of emphysema.

Authors:  Edoardo Cavigli; Gianna Camiciottoli; Stefano Diciotti; Ilaria Orlandi; Cheti Spinelli; Eleonora Meoni; Luca Grassi; Carmela Farfalla; Massimo Pistolesi; Fabio Falaschi; Mario Mascalchi
Journal:  Eur Radiol       Date:  2009-02-18       Impact factor: 5.315

4.  Inter- and intra-software reproducibility of computed tomography lung density measurements.

Authors:  Miranda Kirby; Charles Hatt; Nancy Obuchowski; Stephen M Humphries; Jered Sieren; David A Lynch; Sean B Fain
Journal:  Med Phys       Date:  2020-03-31       Impact factor: 4.071

Review 5.  [HRCT technique with low-dose protocols for interstitial lung diseases].

Authors:  J Ley-Zaporozhan; S Ley
Journal:  Radiologe       Date:  2014-12       Impact factor: 0.635

6.  Effect of smoking cessation on quantitative computed tomography in smokers at risk in a lung cancer screening population.

Authors:  Bertram J Jobst; Oliver Weinheimer; Mila Trauth; Nikolaus Becker; Erna Motsch; Marie-Luise Groß; Jan Tremper; Stefan Delorme; Anke Eigentopf; Monika Eichinger; Hans-Ulrich Kauczor; Mark O Wielpütz
Journal:  Eur Radiol       Date:  2017-09-07       Impact factor: 5.315

7.  Thoracic lymph node delineation at dose-reduced (1 mSv) dose-modulated contrast enhanced MDCT: a retrospective pilot study.

Authors:  Marco Paolini; Kathrin Wirth; Amanda Tufman; Maximilian Reiser; Rudolf M Huber; Ullrich G Mueller-Lisse
Journal:  Radiol Med       Date:  2016-05-06       Impact factor: 3.469

8.  Prevalence and correlates of pulmonary emphysema in smokers and former smokers. A densitometric study of participants in the ITALUNG trial.

Authors:  Gianna Camiciottoli; Edoardo Cavigli; Luca Grassi; Stefano Diciotti; Ilaria Orlandi; Marco Zappa; Giulia Picozzi; Andrea Lopes Pegna; Eugenio Paci; Fabio Falaschi; Mario Mascalchi
Journal:  Eur Radiol       Date:  2008-08-09       Impact factor: 5.315

9.  Fully automatic quantitative assessment of emphysema in computed tomography: comparison with pulmonary function testing and normal values.

Authors:  C P Heussel; F J F Herth; J Kappes; R Hantusch; S Hartlieb; O Weinheimer; H U Kauczor; R Eberhardt
Journal:  Eur Radiol       Date:  2009-05-21       Impact factor: 5.315

10.  Image reconstruction affects computer tomographic assessment of lung hyperinflation.

Authors:  Andreas W Reske; Harald Busse; Marcelo B P Amato; Matthias Jaekel; Thomas Kahn; Peter Schwarzkopf; Dierk Schreiter; Udo Gottschaldt; Matthias Seiwerts
Journal:  Intensive Care Med       Date:  2008-06-08       Impact factor: 17.440

View more