Gadolinium use in spine procedures for patients with allergy to iodinated contrast--experience of 127 procedures.

Y Safriel1, M Ali, M Hayt, R Ang.   

Abstract

BACKGROUND AND
PURPOSE: To review the safety and efficacy of gadolinium as a contrast agent in spine pain management procedures in patients who are at high risk for a contrast reaction and are therefore unacceptable candidates for the use of standard nonionic contrast.
METHODS: We reviewed our records over a 4-year period of interlaminar and foraminal epidural steroid injections, nerve blocks, facet injections, intercostal blocks, and diskograms in the lumbar, thoracic, and cervical spine for cases in which patients had allergies that made them unsuitable candidates for standard nonionic contrast and where gadolinium was used to confirm needle tip placement before injection of medication.
RESULTS: Ninety-two patients underwent 127 procedures. A spinal needle was used in all but 7 procedures. All patients were outpatients and all were discharged without complication after 20 to 45 minutes with follow-up instructions. No delayed complications were reported. Gadolinium was visualized by using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. For epidural steroid injection, the gadolinium dose ranged from 1 to 5 mL, nerve blocks from 0.2 to 1 mL per level, facet injections from 0.2 to 0.5 mL per level, intercostal blocks used 0.5 mL, and diskograms from 1.5 to 7.5 mL per level. The highest dose received by 1 patient was an intradiskal 15.83 mL during a 3-level diskogram.
CONCLUSION: Gadolinium seems to be a safe alternative to standard nonionic contrast in spine pain management procedures in those patients considered to be at high risk for a contrast reaction.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16775262      PMCID: PMC8133924     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  27 in total

1.  Safety and tolerance after intravenous administration of 0.3 mmol/kg Gd-DTPA. Results of a randomized, controlled clinical trial.

Authors:  H P Niendorf; J Haustein; T Louton; W Beck; M Laniado
Journal:  Invest Radiol       Date:  1991-11       Impact factor: 6.016

2.  Is it dangerous to inject magnetic resonance contrast media into the subarachnoid space?

Authors:  I O Skalpe
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

3.  Intrathecal gadolinium (gadopentetate dimeglumine) enhanced magnetic resonance myelography and cisternography: results of a multicenter study.

Authors:  E Turgut Tali; Nil Ercan; Gaida Krumina; Mohammed Rudwan; Angel Mironov; Qing Yu Zeng; J Randy Jinkins
Journal:  Invest Radiol       Date:  2002-03       Impact factor: 6.016

4.  Facet joint injection for low back pain. A clinical study.

Authors:  M C Lynch; J F Taylor
Journal:  J Bone Joint Surg Br       Date:  1986-01

5.  Correct placement of epidural steroid injections: fluoroscopic guidance and contrast administration.

Authors:  D L Renfrew; T E Moore; M H Kathol; G Y el-Khoury; J H Lemke; C W Walker
Journal:  AJNR Am J Neuroradiol       Date:  1991 Sep-Oct       Impact factor: 3.825

Review 6.  Complications associated with epidural steroid injections.

Authors:  S E Abram; T C O'Connor
Journal:  Reg Anesth       Date:  1996 Mar-Apr

7.  Intraspinal therapy using methylprednisolone acetate. Twenty-three years of clinical controversy.

Authors:  D A Nelson
Journal:  Spine (Phila Pa 1976)       Date:  1993-02       Impact factor: 3.468

8.  Epidural injections for the diagnosis and treatment of low-back pain.

Authors:  A H White; R Derby; G Wynne
Journal:  Spine (Phila Pa 1976)       Date:  1980 Jan-Feb       Impact factor: 3.468

9.  Epidurography and therapeutic epidural injections: technical considerations and experience with 5334 cases.

Authors:  B A Johnson; K P Schellhas; S R Pollei
Journal:  AJNR Am J Neuroradiol       Date:  1999-04       Impact factor: 3.825

10.  Safety of gadolinium contrast agent in hemodialysis patients.

Authors:  S Okada; K Katagiri; T Kumazaki; H Yokoyama
Journal:  Acta Radiol       Date:  2001-05       Impact factor: 1.701

View more
  5 in total

1.  Safety of 1000 CT-guided steroid injections with air used to localize the epidural space.

Authors:  A Chang; S Pochert; C Romano; A Brook; T Miller
Journal:  AJNR Am J Neuroradiol       Date:  2011-01-13       Impact factor: 3.825

2.  High-resolution magnetic resonance-guided posterior femoral cutaneous nerve blocks.

Authors:  Jan Fritz; Cary Bizzell; Sudhir Kathuria; Aaron J Flammang; Eric H Williams; Allan J Belzberg; John A Carrino; Avneesh Chhabra
Journal:  Skeletal Radiol       Date:  2012-12-20       Impact factor: 2.199

3.  Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction.

Authors:  Sanjay K Shetty; Erik N Nelson; Tara M Lawrimore; William E Palmer
Journal:  Skeletal Radiol       Date:  2006-12-23       Impact factor: 2.199

4.  Complications and pitfalls of lumbar interlaminar and transforaminal epidural injections.

Authors:  Bradly S Goodman; Lyle W F Posecion; Srinivas Mallempati; Matt Bayazitoglu
Journal:  Curr Rev Musculoskelet Med       Date:  2008-08-15

5.  MR epidurography: distribution of injectate at caudal epidural injection.

Authors:  Darra T Murphy; Eoin C Kavanagh; Ashley Poynton; Vikki O Chan; Michael R Moynagh; Stephen Eustace
Journal:  Skeletal Radiol       Date:  2014-08-02       Impact factor: 2.199

  5 in total