OBJECTIVES: To test whether magnetic resonance (MR) imaging can be used to assess differential lung blood flow as accurately as isotope lung perfusion studies in patients investigated for congenital heart disease. METHODS AND RESULTS: Radionuclide lung perfusion and MR imaging were performed in 12 children with suspected unilateral branch pulmonary artery stenosis (mean age 12.1 (5.9) years, range 3.1-17.2 years). A non-breath hold, fast gradient echo phase contrast MR sequence was used to measure flow in the pulmonary trunk and one pulmonary artery to calculate differential flow. Good agreement was shown between the two imaging methods by Bland-Altman analysis. There was excellent correlation between the radionuclide and MR phase contrast calculated total lung blood flow (r = 0.98, p < 0.0001). CONCLUSION: MR phase contrast is an accurate method for measuring differential total right and left lung blood flow. If MR imaging is performed to assess the branch pulmonary arteries, differential lung blood flow can be also measured, avoiding the need for an additional radionuclide lung perfusion scan and reducing the overall radiation burden to this group of patients.
OBJECTIVES: To test whether magnetic resonance (MR) imaging can be used to assess differential lung blood flow as accurately as isotope lung perfusion studies in patients investigated for congenital heart disease. METHODS AND RESULTS: Radionuclide lung perfusion and MR imaging were performed in 12 children with suspected unilateral branch pulmonary artery stenosis (mean age 12.1 (5.9) years, range 3.1-17.2 years). A non-breath hold, fast gradient echo phase contrast MR sequence was used to measure flow in the pulmonary trunk and one pulmonary artery to calculate differential flow. Good agreement was shown between the two imaging methods by Bland-Altman analysis. There was excellent correlation between the radionuclide and MR phase contrast calculated total lung blood flow (r = 0.98, p < 0.0001). CONCLUSION: MR phase contrast is an accurate method for measuring differential total right and left lung blood flow. If MR imaging is performed to assess the branch pulmonary arteries, differential lung blood flow can be also measured, avoiding the need for an additional radionuclide lung perfusion scan and reducing the overall radiation burden to this group of patients.
Authors: I-Seok Kang; Andrew N Redington; Leland N Benson; Christopher Macgowan; Emanuela R Valsangiacomo; Kevin Roman; Christian J Kellenberger; Shi-Joon Yoo Journal: Circulation Date: 2003-05-27 Impact factor: 29.690
Authors: W G Hundley; L D Hillis; C A Hamilton; R J Applegate; D M Herrington; G D Clarke; G A Braden; M S Thomas; R A Lange; R M Peshock; K M Link Journal: Circulation Date: 2000-05-23 Impact factor: 29.690
Authors: Kevin S Roman; Christian J Kellenberger; Saqba Farooq; Christopher K MacGowan; David L Gilday; Shi-Joon Yoo Journal: Pediatr Radiol Date: 2004-10-15
Authors: D N Firmin; G L Nayler; R H Klipstein; S R Underwood; R S Rees; D B Longmore Journal: J Comput Assist Tomogr Date: 1987 Sep-Oct Impact factor: 1.826
Authors: Sara L Partington; Anne Marie Valente; Michael Landzberg; Frederick Grant; Marcelo F Di Carli; Sharmila Dorbala Journal: J Nucl Cardiol Date: 2015-07-01 Impact factor: 5.952
Authors: Kang Wang; Mark L Schiebler; Christopher J Francois; A Munoz Del Rio; Ma Daniela Cornejo; Laura C Bell; Frank R Korosec; Jean H Brittain; James H Holmes; Scott K Nagle Journal: J Magn Reson Imaging Date: 2013-01-24 Impact factor: 4.813
Authors: Boban Thomas; José Diogo Ferreira Martins; Nuno Jalles Tavares; Artur Lopes; Fátima F Pinto; José Fragata Journal: Ann Pediatr Cardiol Date: 2013-01