Literature DB >> 16774866

Dynamics of oropharyngeal aerosol transport and deposition with the realistic flow pattern.

Tomasz R Sosnowski1, Arkadiusz Moskal, Leon Gradoń.   

Abstract

Aerosol flow and deposition in the model of human oropharynx was studied theoretically and experimentally for two realistic inspiratory patterns. The three-dimensional (3D) airflow structure in the sample geometry was solved with the computational fluid dynamics (CFD) code (Fluent), used to calculate dynamic distribution of particle deposition (0.3-10 mum). Experiments were done for the same flow conditions using the silicone-rubber cast with the matching geometry. Nonsteady breathing flows were reproduced with the computer-controlled artificial lung apparatus. Results of computations show that particles smaller than 3 mum easily pass the oropharynx during inspiration, while particles with a size close to 10 mum are substantially deposited, preferentially in the region of the naso-pharyngeal bend. For particles in the submicrometer size range, the spatial and temporal deposition pattern is more complicated, and strongly depends on breathing dynamics. The experiments confirmed that the mass median diameter (MMD) of the aerosol that penetrates the oropharynx and flows to the tracheobronchial tree is reduced. Measured total mass efficiency of deposition of the tested aerosol was in the range of 35-60%, depending on the breathing pattern. These findings are consistent with the CFD results. The methods and the preliminary results enable a more realistic analysis of dynamic effects during the flow of inhaled particles through the complex geometry of the oropharynx. Such analysis is needed for estimation of toxic potential of aerosols, related to their local deposition in different parts of the respiratory tract.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16774866     DOI: 10.1080/08958370600748737

Source DB:  PubMed          Journal:  Inhal Toxicol        ISSN: 0895-8378            Impact factor:   2.724


  4 in total

1.  Effect of intersubject variability of extrathoracic morphometry, lung airways dimensions and respiratory parameters on particle deposition.

Authors:  Majid Hussain; Winker-Heil Renate; Hofmann Werner
Journal:  J Thorac Dis       Date:  2011-09       Impact factor: 2.895

Review 2.  In silico models of aerosol delivery to the respiratory tract - development and applications.

Authors:  P Worth Longest; Landon T Holbrook
Journal:  Adv Drug Deliv Rev       Date:  2011-05-27       Impact factor: 15.470

3.  Targeted Lung Delivery of Nasally Administered Aerosols.

Authors:  Geng Tian; Michael Hindle; P Worth Longest
Journal:  Aerosol Sci Technol       Date:  2014       Impact factor: 2.908

4.  Development of a three-dimensional model of the human respiratory system for dosimetric use.

Authors:  Jacky A Rosati Rowe; Ray Burton; George McGregor; Rob McCauley; Wei Tang; Richard Spencer
Journal:  Theor Biol Med Model       Date:  2013-05-01       Impact factor: 2.432

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.