The effect of applied sensor contact force on pulse transit time.

X F Teng1, Y T Zhang.   

Abstract

Pulse transit time (PTT) is usually determined as the time interval between the peak of the electrocardiogram (ECG) R wave and a characteristic point of the peripheral pulse measured by photoplethysmography. However, it was found that the photoplethysmogram (PPG) is affected by the contact force between the photoplethysmographic sensor and the measurement site, i.e. finger. Therefore, we hypothesized that the PTT may be altered by the applied sensor contact force. An ECG and PPG were recorded simultaneously from 30 healthy subjects using 12 magnitudes of contact force (0.1 N-1.8 N). Three characteristic points of the PPG were selected to determine the PTT, including the points near the foot (PTT1), on the systole phase (PTT2) and near the peak (PTT3). Both PTT1 and PTT2 increased significantly (p = 0.014 for PTT1 and p = 0.038 for PTT2) with the sensor contact force until the transmural force reached -0.1 N. With further increase in the contact force, they kept at an almost constant level. Such a changing trend was not found in PTT3. The results of this study suggest that the applied sensor contact force should be carefully controlled in PTT measurement to avoid diminishing its value as a diagnostic tool.

Mesh:

Year:  2006        PMID: 16772666     DOI: 10.1088/0967-3334/27/8/002

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  11 in total

1.  Change in pulse transit time and pre-ejection period during head-up tilt-induced progressive central hypovolaemia.

Authors:  Gregory S H Chan; Paul M Middleton; Branko G Celler; Lu Wang; Nigel H Lovell
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

2.  The acute effects of running on blood pressure estimation using pulse transit time in normotensive subjects.

Authors:  Mico Yee-Man Wong; Emma Pickwell-MacPherson; Yuan-Ting Zhang
Journal:  Eur J Appl Physiol       Date:  2009-06-20       Impact factor: 3.078

3.  Interoceptive awareness in experienced meditators.

Authors:  Sahib S Khalsa; David Rudrauf; Antonio R Damasio; Richard J Davidson; Antoine Lutz; Daniel Tranel
Journal:  Psychophysiology       Date:  2008-05-20       Impact factor: 4.016

4.  Skin inhomogeneity as a source of error in remote PPG-imaging.

Authors:  Andreia Vieira Moço; Sander Stuijk; Gerard de Haan
Journal:  Biomed Opt Express       Date:  2016-10-26       Impact factor: 3.732

Review 5.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

6.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

7.  Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.

Authors:  Marit H N van Velzen; Arjo J Loeve; Sjoerd P Niehof; Egbert G Mik
Journal:  Med Biol Eng Comput       Date:  2017-03-30       Impact factor: 2.602

8.  Quantitative Comparison of the Performance of Piezoresistive, Piezoelectric, Acceleration, and Optical Pulse Wave Sensors.

Authors:  Hongju Wang; Lu Wang; Nannan Sun; Yang Yao; Liling Hao; Lisheng Xu; Stephen E Greenwald
Journal:  Front Physiol       Date:  2020-01-14       Impact factor: 4.566

Review 9.  Sources of Inaccuracy in Photoplethysmography for Continuous Cardiovascular Monitoring.

Authors:  Jesse Fine; Kimberly L Branan; Andres J Rodriguez; Tananant Boonya-Ananta; Jessica C Ramella-Roman; Michael J McShane; Gerard L Coté
Journal:  Biosensors (Basel)       Date:  2021-04-16

10.  Piezoresistive Soft Condensed Matter Sensor for Body-Mounted Vital Function Applications.

Authors:  Mark Melnykowycz; Michael Tschudin; Frank Clemens
Journal:  Sensors (Basel)       Date:  2016-03-04       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.