Abstract

The aim of this study was to investigate the radiation exposure of the hands and thyroid glands of orthopaedic surgeon and assistant during procedures involving percutaneous wiring of the hand and wrist. The radiation dose to the hand and thyroid glands was prospectively studied from a total of 30 percutaneous hand and wrist procedures. Four thermolucent densitometers were used to measure the radiation exposure. Cases were divided depending on fracture location (ie. wrist, metacarpal, phalangeal) and surgical experience (i.e. Senior House Officer, Registrar, Consultant). Mean radiation exposure in the hand for the surgeon was 0.80 mSv and 0.87 mSv for the assistant. There was a significant difference in the unshielded thyroid group compared to the shielded thyroid group (p < 0.05). The duration and number of exposure decreases with increasing experience. We also found a trend whereas we operate from proximal to distal (wrist to phalangeal), the total direct hand exposure increases. Radiation exposure in the hands and thyroid glands during percutaneous wiring of hand and wrist procedures were within the recommended limit. However, for the junior orthopaedic trainee, the risk of over radiating oneself is higher as the duration and number of exposure increases. We recommended the use of thyroid shield and adherence to the ALARA principle in any fluoroscopic assisted procedures. Routine monitoring of radiation exposure is essential in preventing radiation related disease.

Entities:  

Mesh:

Year:  2006        PMID: 16768265

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  9 in total

1.  Computer-assisted percutaneous scaphoid fixation: concepts and evolution.

Authors:  Erin J Smith; Randy E Ellis; David R Pichora
Journal:  J Wrist Surg       Date:  2013-11

2.  Radiation Exposure and Hand Dominance Using Mini C-Arm Fluoroscopy in Hand Surgery.

Authors:  Corey B Fuller; Montri D Wongworawat; Barth B Riedel
Journal:  Hand (N Y)       Date:  2016-02-02

3.  Radiation Exposure of the Hand and Chest during C-arm Fluoroscopy-Guided Procedures.

Authors:  Cheol Hee Jung; Jae Sung Ryu; Seung Woo Baek; Ji Hye Oh; Nam Sik Woo; Hae Kyoung Kim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2013-01-04

4.  Perception of quality of intraoperative fluoroscopy and the influence on postoperative management: an international survey.

Authors:  Florian Oehme; Konrad Schütze; Björn Christian Link; Herman Frima; Tim Schepers; Steven Rhemrev; Mark Rickman; Reto Babst; Frank Joseph Paulus Beeres
Journal:  Eur J Trauma Emerg Surg       Date:  2019-12-20       Impact factor: 3.693

5.  Three-Dimensional Printed Targeting Device for Scaphoid Fracture Fixation.

Authors:  Matthew C DeWolf; Alexander Hartov; Thomas A Fortney; Lance G Warhold
Journal:  Hand (N Y)       Date:  2020-02-28

6.  Awareness and attitudes amongst basic surgical trainees regarding radiation in orthopaedic trauma surgery.

Authors:  Fr Khan; Z Ul-Abadin; S Rauf; A Javed
Journal:  Biomed Imaging Interv J       Date:  2010-07-01

Review 7.  Intraoperative radiation safety in orthopaedics: a review of the ALARA (As low as reasonably achievable) principle.

Authors:  Daniel J Kaplan; Jay N Patel; Frank A Liporace; Richard S Yoon
Journal:  Patient Saf Surg       Date:  2016-12-12

8.  K-wire Made Easy by Premarking Wire Trajectory on the Skin in Management of Finger Fractures.

Authors:  Adnan Ghazi Gelidan; Ahad Bugis; Layla Al-Shammari; Nojoud Omaish; Sadem Al-Sharif; Saad Al-Juhayyiam; Reem Bakraa; Mohammed Rustom
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-09-17

9.  Radiation exposure for intraoperative 3D scans in a hybrid operating room: how to reduce radiation exposure for the surgical team.

Authors:  K Schuetze; M Kraus; A Eickhoff; F Gebhard; P H Richter
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-29       Impact factor: 2.924

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.