Literature DB >> 16768241

Statistical strategy for anisotropic adventitia modelling in IVUS.

Debora Gil1, Aura Hernández, Oriol Rodriguez, Josepa Mauri, Petia Radeva.   

Abstract

Vessel plaque assessment by analysis of intravascular ultrasound sequences is a useful tool for cardiac disease diagnosis and intervention. Manual detection of luminal (inner) and media-adventitia (external) vessel borders is the main activity of physicians in the process of lumen narrowing (plaque) quantification. Difficult definition of vessel border descriptors, as well as, shades, artifacts, and blurred signal response due to ultrasound physical properties trouble automated adventitia segmentation. In order to efficiently approach such a complex problem, we propose blending advanced anisotropic filtering operators and statistical classification techniques into a vessel border modelling strategy. Our systematic statistical analysis shows that the reported adventitia detection achieves an accuracy in the range of interobserver variability regardless of plaque nature, vessel geometry, and incomplete vessel borders.

Entities:  

Mesh:

Year:  2006        PMID: 16768241     DOI: 10.1109/tmi.2006.874962

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  Assessment of image features for vessel wall segmentation in intravascular ultrasound images.

Authors:  Lucas Lo Vercio; José Ignacio Orlando; Mariana Del Fresno; Ignacio Larrabide
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-01-25       Impact factor: 2.924

2.  Introduction to the special section on computer vision for intravascular and intracardiac imaging.

Authors:  Gozde Unal; Greg Slabaugh; Ioannis A Kakadiaris; Allen Tannenbaum
Journal:  IEEE Trans Inf Technol Biomed       Date:  2008-05

3.  Computer Vision Techniques for Transcatheter Intervention.

Authors:  Feng Zhao; Xianghua Xie; Matthew Roach
Journal:  IEEE J Transl Eng Health Med       Date:  2015-06-18       Impact factor: 3.316

4.  Combination of the Level-Set Methods with the Contourlet Transform for the Segmentation of the IVUS Images.

Authors:  Hassen Lazrag; Med Saber Naceur
Journal:  Int J Biomed Imaging       Date:  2012-05-22

5.  Coronary Plaque Boundary Enhancement in IVUS Image by Using a Modified Perona-Malik Diffusion Filter.

Authors:  S Anam; E Uchino; N Suetake
Journal:  Int J Biomed Imaging       Date:  2014-11-24

6.  Automatic lumen segmentation in IVOCT images using binary morphological reconstruction.

Authors:  Matheus Cardoso Moraes; Diego Armando Cardona Cardenas; Sérgio Shiguemi Furuie
Journal:  Biomed Eng Online       Date:  2013-08-09       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.