Literature DB >> 16767742

Quantitative CBV measurement from static T1 changes in tissue and correction for intravascular water exchange.

Wanyong Shin1, Ty A Cashen, Sandra W Horowitz, Rahul Sawlani, Timothy J Carroll.   

Abstract

The steady-state (SS) approach has been proposed to measure quantitative cerebral blood volume (CBV). However, it is known that the CBV value in SS (CBVSS) is subject to error resulting from the effects of water diffusion from the intra- to extravascular space. CBVSS measurements were simulated in both fast- and no-water-exchange limits, and compared with measured CBVSS values to determine which limiting case is appropriate. Twenty-eight patients were scanned with a segmented Look-Locker echo-planar imaging (LL-EPI) sequence before and after the injection of 0.1 mmol/kg of a T1-shortening contrast agent. Signal changes and T1 values of brain parenchyma and the blood pool were measured pre- and postcontrast. These signal changes and T1 values, in combination with the simulated results, were used to estimate water-exchange rates. We found that the intra- to extravascular water-exchange rates in white matter (WM) and gray matter (GM) were 0.9 and 1.6 s-1, respectively. With these water-exchange rates, the fast-water-exchange limit of the CBV values showed good agreement with the simulation (r=0.86 in WM, and 0.78 in GM). The CBV values with the correction for water-exchange effects were recalculated as 2.73+/-0.44 and 5.81+/-1.12 of quantitative cerebral blood water volume (%) in WM and GM, respectively. Copyright (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16767742     DOI: 10.1002/mrm.20937

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

1.  Correction for arterial-tissue delay and dispersion in absolute quantitative cerebral perfusion DSC MR imaging.

Authors:  Jessy J Mouannes-Srour; Wanyong Shin; Sameer A Ansari; Michael C Hurley; Parmede Vakil; Bernard R Bendok; John L Lee; Colin P Derdeyn; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  SCALE-PWI: A pulse sequence for absolute quantitative cerebral perfusion imaging.

Authors:  Jessy Mouannes Srour; Wanyong Shin; Saurabh Shah; Anindya Sen; Timothy J Carroll
Journal:  J Cereb Blood Flow Metab       Date:  2010-12-15       Impact factor: 6.200

3.  First results in an MR imaging--compatible canine model of acute stroke.

Authors:  A Shaibani; S Khawar; W Shin; T A Cashen; B Schirf; M Rohany; S Kakodkar; T J Carroll
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

4.  Quantitative cerebral blood flow in dynamic susceptibility contrast MRI using total cerebral flow from phase contrast magnetic resonance angiography.

Authors:  David Bonekamp; Mahaveer Degaonkar; Peter B Barker
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

5.  Decreased frontal lobe gray matter perfusion in cognitively impaired patients with secondary-progressive multiple sclerosis detected by the bookend technique.

Authors:  R I Aviv; P L Francis; R Tenenbein; P O'Connor; L Zhang; A Eilaghi; L Lee; T J Carroll; J Mouannes-Srour; A Feinstein
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

6.  Quantification of cerebral perfusion using the "bookend technique": an evaluation in CNS tumors.

Authors:  Timothy J Carroll; Sandra Horowitz; Wanyong Shin; Jessy Mouannes; Rahul Sawlani; Saad Ali; Jeffrey Raizer; Stephen Futterer
Journal:  Magn Reson Imaging       Date:  2008-06-05       Impact factor: 2.546

Review 7.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

8.  Absolute quantification of perfusion by dynamic susceptibility contrast MRI using Bookend and VASO steady-state CBV calibration: a comparison with pseudo-continuous ASL.

Authors:  Emelie Lindgren; Ronnie Wirestam; Karin Markenroth Bloch; André Ahlgren; Matthias J P van Osch; Danielle van Westen; Yulia Surova; Freddy Ståhlberg; Linda Knutsson
Journal:  MAGMA       Date:  2014-02-26       Impact factor: 2.310

9.  Leakage and water exchange characterization of gadofosveset in the myocardium.

Authors:  Octavia Bane; Daniel C Lee; Brandon C Benefield; Kathleen R Harris; Neil R Chatterjee; James C Carr; Timothy J Carroll
Journal:  Magn Reson Imaging       Date:  2013-12-07       Impact factor: 2.546

10.  Contrast agent dose effects in cerebral dynamic susceptibility contrast magnetic resonance perfusion imaging.

Authors:  Jeffry R Alger; Timothy J Schaewe; Tom C Lai; Andrew J Frew; Paul M Vespa; Maria Etchepare; David S Liebeskind; Jeffrey L Saver; S Chelsea Kidwell
Journal:  J Magn Reson Imaging       Date:  2009-01       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.