Literature DB >> 16764444

Extended high-frame rate imaging method with limited-diffraction beams.

Jiqi Cheng1, Jian-yu Lu.   

Abstract

Fast three-dimensional (3-D) ultrasound imaging is a technical challenge. Previously, a high-frame rate (HFR) imaging theory was developed in which a pulsed plane wave was used in transmission, and limited-diffraction array beam weightings were applied to received echo signals to produce a spatial Fourier transform of object function for 3-D image reconstruction. In this paper, the theory is extended to include explicitly various transmission schemes such as multiple limited-diffraction array beams and steered plane waves. A relationship between the limited-diffraction array beam weighting of received echo signals and a 2-D Fourier transform of the same signals over a transducer aperture is established. To verify the extended theory, computer simulations, in vitro experiments on phantoms, and in vivo experiments on the human kidney and heart were performed. Results show that image resolution and contrast are increased over a large field of view as more and more limited-diffraction array beams with different parameters or plane waves steered at different angles are used in transmissions. Thus, the method provides a continuous compromise between image quality and image frame rate that is inversely proportional to the number of transmissions used to obtain a single frame of image. From both simulations and experiments, the extended theory holds a great promise for future HFR 3-D imaging.

Entities:  

Mesh:

Year:  2006        PMID: 16764444     DOI: 10.1109/tuffc.2006.1632680

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  13 in total

1.  Accurate ultrasound imaging based on range point migration method for the depiction of fetal surface.

Authors:  Hirofumi Taki; Shinya Tanimura; Takuya Sakamoto; Tsuyoshi Shiina; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2014-09-13       Impact factor: 1.314

2.  Simultaneous Axial Multifocal Imaging Using a Single Acoustical Transmission: A Practical Implementation.

Authors:  Asaf Ilovitsh; Tali Ilovitsh; Josquin Foiret; Douglas N Stephens; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-05       Impact factor: 2.725

3.  Stolt's f-k migration for plane wave ultrasound imaging.

Authors:  Damien Garcia; Louis Le Tarnec; Stéphan Muth; Emmanuel Montagnon; Jonathan Porée; Guy Cloutier
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

4.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  J Med Ultrason (2001)       Date:  2011-05-07       Impact factor: 1.314

Review 5.  New developments in paediatric cardiac functional ultrasound imaging.

Authors:  Chris L de Korte; Maartje M Nillesen; Anne E C M Saris; Richard G P Lopata; Johan M Thijssen; Livia Kapusta
Journal:  J Med Ultrason (2001)       Date:  2013-12-20       Impact factor: 1.314

6.  Phase Modulation Beamforming for Ultrafast Plane-Wave Imaging.

Authors:  Bowen Jing; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-05-11       Impact factor: 2.725

7.  Application of X-Y separable 2-D array beamforming for increased frame rate and energy efficiency in handheld devices.

Authors:  Kevin Owen; Michael Fuller; John Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-07       Impact factor: 2.725

8.  Single-heartbeat electromechanical wave imaging with optimal strain estimation using temporally unequispaced acquisition sequences.

Authors:  Jean Provost; Stéphane Thiébaut; Jianwen Luo; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2012-02-01       Impact factor: 3.609

9.  A submatrix spatial coherence approach to minimum variance beamforming combined with sign coherence factor for coherent plane wave compounding.

Authors:  Xin Yan; Yuanyuan Wang
Journal:  Technol Health Care       Date:  2022       Impact factor: 1.205

10.  High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence.

Authors:  Anthony S Podkowa; Michael L Oelze; Jeffrey A Ketterling
Journal:  Appl Sci (Basel)       Date:  2018-02-01       Impact factor: 2.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.