Literature DB >> 16757876

Radiation exposure in body computed tomography examinations of trauma patients.

M Kortesniemi1, T Kiljunen, A Kangasmäki.   

Abstract

Multi-slice CT provides an efficient imaging modality for trauma imaging. The purpose of this study was to provide absorbed and effective dose data from CT taking into account the patient size and compare such doses with the standard CT dose quantities based on standard geometry. The CT examination data from abdominal and thoracic scan series were collected from 36 trauma patients. The CTDI(vol), DLP(w) and effective dose were determined, and the influence of patient size was applied as a correction factor to calculated doses. The patient size was estimated from the patient weight as the effective radius based on the analysis from the axial images of abdominal and thoracic regions. The calculated mean CTDI(vol), DLP(w) and effective dose were 15.2 mGy, 431 mGy cm and 6.5 mSv for the thorax scan, and 18.5 mGy, 893 mGy cm and 14.8 mSv for the abdomen scan, respectively. The doses in the thorax and abdomen scans taking the patient size into account were 34% and 9% larger than the standard dose quantities, respectively. The use of patient size in dose estimation is recommended in order to provide realistic data for evaluation of the radiation exposure in CT, especially for paediatric patients and smaller adults.

Entities:  

Mesh:

Year:  2006        PMID: 16757876     DOI: 10.1088/0031-9155/51/12/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b.

Authors:  Tim F Weber; Maria-Katharina Ganten; Dittmar Böckler; Philipp Geisbüsch; Annette Kopp-Schneider; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Eur Radiol       Date:  2008-07-22       Impact factor: 5.315

2.  Inadvertent thyroid irradiation in protocol-driven trauma CT: a survey of hospital ERs.

Authors:  Stephen R Baker; Yih-Hann H Hsieh; Pierre D Maldjian; Michael T Scanlan
Journal:  Emerg Radiol       Date:  2009-01-09

3.  Patient dose considerations in computed tomography examinations.

Authors:  Ioannis A Tsalafoutas; Georgios V Koukourakis
Journal:  World J Radiol       Date:  2010-07-28

4.  Cumulative doses analysis in young trauma patients: a single-centre experience.

Authors:  Sergio Salerno; Maurizio Marrale; Claudia Geraci; Giuseppe Caruso; Giuseppe Lo Re; Antonio Lo Casto; Massimo Midiri
Journal:  Radiol Med       Date:  2015-09-19       Impact factor: 3.469

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.