Peripheral dose outside applicators in electron beams.

James C L Chow1, Grigor N Grigorov.   

Abstract

The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm(2) cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm(2) cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 degrees.

Mesh:

Year:  2006        PMID: 16757855     DOI: 10.1088/0031-9155/51/12/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Excessive applicator radiation leakage for a common therapeutic kilovoltage system.

Authors:  Brad Beeksma; Joerg Lehmann
Journal:  Br J Radiol       Date:  2018-11-15       Impact factor: 3.039

2.  Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

Authors:  Collins Yeboah; Alex Karotki; Dylan Hunt; Rick Holly
Journal:  J Appl Clin Med Phys       Date:  2010-06-15       Impact factor: 2.102

3.  Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

Authors:  Mohamad M Alabdoaburas; Jean-Pierre Mege; Jean Chavaudra; Jérémi Vũ Bezin; Atilla Veres; Florent de Vathaire; Dimitri Lefkopoulos; Ibrahima Diallo
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

4.  Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy.

Authors:  Joann I Prisciandaro; Akash Makkar; Colleen J Fox; James A Hayman; Laura Horwood; Frank Pelosi; Jean M Moran
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

5.  Shielding effect of a lead apron on the peripheral radiation dose outside the applicator of electron beams from an Elekta linear accelerator.

Authors:  Huifang He; Yingdong Zhang; Jidong Wang; Xingyu Chen; Yuyan Yang; Junjie Wang
Journal:  J Appl Clin Med Phys       Date:  2020-12-09       Impact factor: 2.102

6.  Verification of electron beam parameters in an intraoperative linear accelerator using dosimetric and radiobiological response methods.

Authors:  Agnieszka Dróżdż; Martyna Waluś; Marcin Zieliński; Bożena Malesa; Marta Kruszyna-Mochalska; Katarzyna Kulcenty; Beata Adamczyk; Piotr Nowaczyk; Julian Malicki; Jacek Pracz
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30

7.  Nontarget and Out-of-Field Doses from Electron Beam Radiotherapy.

Authors:  Natalia Matuszak; Marta Kruszyna-Mochalska; Agnieszka Skrobala; Adam Ryczkowski; Piotr Romanski; Igor Piotrowski; Katarzyna Kulcenty; Wiktoria Maria Suchorska; Julian Malicki
Journal:  Life (Basel)       Date:  2022-06-08

8.  Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

Authors:  Carlos E Cardenas; Paige L Nitsch; Rajat J Kudchadker; Rebecca M Howell; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102