Literature DB >> 16755584

Efficacy of small reconstruction plates in vascularized bone graft mandibular reconstruction.

D Gregory Farwell1, Eric J Kezirian, Jennifer L Heydt, Bevan Yueh, Neal D Futran.   

Abstract

BACKGROUND: Utilization of vascularized bone grafts rigidly fixated with titanium reconstruction plates is the method of choice for reconstruction of segmental mandibular defects. We hypothesized that the use of the newer 2.0-mm locking reconstruction plate (LRP) is not associated with higher rates of complications when compared with larger, previously used plating systems.
METHODS: A retrospective case series of 184 patients undergoing 185 vascularized bone graft reconstruction procedures of the mandible was conducted.
RESULTS: There were 37 plate complications. There was no significant difference in complication rates for the 2 most used plate types (14.5% with the 2.0-mm LRP and 22.2% with the 2.4-mm LRP).
CONCLUSIONS: Use of the smaller 2.0-mm LRP was not associated with an increase in the complications of plate fracture, exposure, infection, or nonunion. Because of its lower profile and ease of application, the 2.0-mm LRP is our plate of choice for mandibular reconstruction. Copyright 2006 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16755584     DOI: 10.1002/hed.20455

Source DB:  PubMed          Journal:  Head Neck        ISSN: 1043-3074            Impact factor:   3.147


  5 in total

1.  Locking versus nonlocking plates in mandibular reconstruction with fibular graft--a biomechanical ex vivo study.

Authors:  Susanne Trainotti; Stefan Raith; Marco Kesting; Stefan Eichhorn; Florian Bauer; Andreas Kolk; Bernd Lethaus; Frank Hölzle; Timm Steiner
Journal:  Clin Oral Investig       Date:  2013-09-22       Impact factor: 3.573

2.  Hardware removal after osseous free flap reconstruction.

Authors:  Kristine E Day; Renee Desmond; J Scott Magnuson; William R Carroll; Eben L Rosenthal
Journal:  Otolaryngol Head Neck Surg       Date:  2013-11-07       Impact factor: 3.497

3.  Unicortical Bone Necrosis of the Fibula Free Flap Associated to the Fixation with a Nonlocking 2.0-mm Reconstruction Plate and Screws.

Authors:  Gustavo N Pereira; Diogo Ribeiro; Luís Saraiva; Hugo Freitas; Ana R Santos
Journal:  Arch Plast Surg       Date:  2022-05-27

4.  Surgical Management of Edentulous Atrophic Mandible Fractures in the Elderly.

Authors:  Nam Seok Chee; Seong June Park; Min Ho Son; Eoy Jung Lee; Soo Woon Lee
Journal:  Maxillofac Plast Reconstr Surg       Date:  2014-09-30

5.  Surgical site infections following oral cavity cancer resection and reconstruction is a risk factor for plate exposure.

Authors:  Christopher M Yao; Hedyeh Ziai; Gordon Tsang; Andrea Copeland; Dale Brown; Jonathan C Irish; Ralph W Gilbert; David P Goldstein; Patrick J Gullane; John R de Almeida
Journal:  J Otolaryngol Head Neck Surg       Date:  2017-04-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.