Literature DB >> 16752625

Implant-retained mandibular overdentures versus conventional dentures: 10 years of care and aftercare.

Anita Visser1, Henny J A Meijer, Gerry M Raghoebar, Arjan Vissink.   

Abstract

PURPOSE: This 10-year prospective, randomized, clinical trial investigated the treatment outcome of edentulous patients treated with mandibular overdentures retained by 2 endosseous implants compared with conventional dentures in patients with or without vestibuloplasty.
MATERIALS AND METHODS: One hundred fifty-one edentulous patients (5 groups) with a symphyseal mandibular bone height between 8 and 25 mm participated. Sixty-two patients were treated with an overdenture retained by 2 implants (groups 1 and 3), 59 patients were treated with a conventional denture (groups 2 and 5), and 30 patients were treated with a conventional denture after preprosthetic vestibuloplasty (group 4). Patients who received conventional dentures but preferred implants later on could undergo implant surgery after 1 year of their initial treatment, but were analyzed in their original group. The prosthetic and surgical care and aftercare were scored during a 10-year evaluation period.
RESULTS: One hundred thirty-three patients completed the 10-year follow-up evaluations. Forty-four percent of patients treated with conventional dentures switched within 10 years to implant-retained overdentures, versus 16% of the patients who were treated with conventional dentures after vestibuloplasty. On average, a greater time investment and more treatment sessions were needed in patients treated with implant-retained overdentures compared to patients treated with conventional dentures.
CONCLUSION: Patients treated with an implant-retained overdenture need more treatment interventions and treatment time than patients treated with conventional dentures.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16752625

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  10 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

Review 4.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

5.  Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: Retrospective study of a cohort of edentulous patients.

Authors:  Lucia Fernandez-Estevan; Eduardo J Selva-Otaolaurruchi; Javier Montero; Fernanda Sola-Ruiz
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

6.  Mandibular implant-supported overdentures in (frail) elderly: A prospective study with 20-year follow-up.

Authors:  Mieke H Bakker; Arjan Vissink; Henny J A Meijer; Gerry M Raghoebar; Anita Visser
Journal:  Clin Implant Dent Relat Res       Date:  2019-04-16       Impact factor: 3.932

7.  The Patient's Denture Assessment (Thai version) is a valid and reliable tool for evaluating the outcome of treatment with complete denture.

Authors:  Sahaprom Namano; Orapin Komin
Journal:  BMC Oral Health       Date:  2021-02-08       Impact factor: 2.757

8.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar

9.  Surface roughness implant-retained mandibular bar and ball joint overdentures and adherence of microorganisms.

Authors:  Valenzuela Rocío; Daniel Valenzuela
Journal:  Eur J Dent       Date:  2018 Oct-Dec

Review 10.  Evaluation of the quality of life and satisfaction in patients using complete dentures versus mandibular overdentures. Systematic review and meta-analysis.

Authors:  Sonia Egido Moreno; Raul Ayuso Montero; Mayra Schemel Suárez; Joan Valls Roca-Umbert; Keila Izquierdo Gómez; José López López
Journal:  Clin Exp Dent Res       Date:  2020-11-18
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.