Literature DB >> 16737740

An integrative transcranial magnetic stimulation mapping technique using non-linear curve fitting.

Alexandra S Kohl1, Adriana Bastos Conforto, Werner J Z'Graggen, Alain Kaelin-Lang.   

Abstract

The aim of this study is to develop a new simple method for analyzing one-dimensional transcranial magnetic stimulation (TMS) mapping studies in humans. Motor evoked potentials (MEP) were recorded from the abductor pollicis brevis (APB) muscle during stimulation at nine different positions on the scalp along a line passing through the APB hot spot and the vertex. Non-linear curve fitting according to the Levenberg-Marquardt algorithm was performed on the averaged amplitude values obtained at all points to find the best-fitting symmetrical and asymmetrical peak functions. Several peak functions could be fitted to the experimental data. Across all subjects, a symmetric, bell-shaped curve, the complementary error function (erfc) gave the best results. This function is characterized by three parameters giving its amplitude, position, and width. None of the mathematical functions tested with less or more than three parameters fitted better. The amplitude and position parameters of the erfc were highly correlated with the amplitude at the hot spot and with the location of the center of gravity of the TMS curve. In conclusion, non-linear curve fitting is an accurate method for the mathematical characterization of one-dimensional TMS curves. This is the first method that provides information on amplitude, position and width simultaneously.

Entities:  

Mesh:

Year:  2006        PMID: 16737740     DOI: 10.1016/j.jneumeth.2006.04.018

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  2 in total

1.  NeuroMeasure: A Software Package for Quantification of Cortical Motor Maps Using Frameless Stereotaxic Transcranial Magnetic Stimulation.

Authors:  Michael B Gerber; Alasdair C McLean; Samuel J Stephen; Alex G Chalco; Usman M Arshad; Gary W Thickbroom; Josh Silverstein; K Zoe Tsagaris; Amy Kuceyeski; Kathleen Friel; Taiza E G Santos; Dylan J Edwards
Journal:  Front Neuroinform       Date:  2019-04-16       Impact factor: 4.081

2.  Effects of post-deposition annealing ambient on band alignment of RF magnetron-sputtered Y2O3 film on gallium nitride.

Authors:  Hock Jin Quah; Kuan Yew Cheong
Journal:  Nanoscale Res Lett       Date:  2013-01-29       Impact factor: 4.703

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.