Literature DB >> 16737218

Following aptamer-thrombin binding by force measurements.

Bernhard Basnar1, Roey Elnathan, Itamar Willner.   

Abstract

The rupture forces between an aptamer (1)-functionalized AFM tip and a thrombin-modified Au surface are analyzed. The rupture force for a single aptamer/thrombin complex is determined as approximately 4.45 pN. The analysis of the system reveals that the rupture forces correspond to the melting of the G-quadruplex structure of the aptamer bound to the thrombin. This melting of the G-quadruplex leads to the dissociation of the aptamer/thrombin complex.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16737218     DOI: 10.1021/ac052289e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Ultrasensitive aptamer-based protein detection via a dual amplified biocatalytic strategy.

Authors:  Yun Xiang; Yuyong Zhang; Xiaoqing Qian; Yaqin Chai; Joseph Wang; Ruo Yuan
Journal:  Biosens Bioelectron       Date:  2010-04-14       Impact factor: 10.618

2.  A polycatenated DNA scaffold for the one-step assembly of hierarchical nanostructures.

Authors:  Yossi Weizmann; Adam B Braunschweig; Ofer I Wilner; Zoya Cheglakov; Itamar Willner
Journal:  Proc Natl Acad Sci U S A       Date:  2008-04-07       Impact factor: 11.205

Review 3.  [Application of atomic force microscopy-based single molecule force spectroscopy in G-quadruplex studies].

Authors:  Wenjing Liu; Tong Sun; Ping Zhang; Lin Li; Junhong Lv; Bin Li
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-08-30

4.  Characterization of enhanced monovalent and bivalent thrombin DNA aptamer binding using single molecule force spectroscopy.

Authors:  Isabel Neundlinger; Alexandra Poturnayova; Ivana Karpisova; Christian Rankl; Peter Hinterdorfer; Maja Snejdarkova; Tibor Hianik; Andreas Ebner
Journal:  Biophys J       Date:  2011-10-05       Impact factor: 4.033

5.  An electrochemical chlorpyrifos aptasensor based on the use of a glassy carbon electrode modified with an electropolymerized aptamer-imprinted polymer and gold nanorods.

Authors:  Mahmoud Roushani; Azizollah Nezhadali; Zeynab Jalilian
Journal:  Mikrochim Acta       Date:  2018-11-15       Impact factor: 5.833

6.  A reusable impedimetric aptasensor for detection of thrombin employing a graphite-epoxy composite electrode.

Authors:  Cristina Ocaña; Mercè Pacios; Manel del Valle
Journal:  Sensors (Basel)       Date:  2012-03-06       Impact factor: 3.576

Review 7.  Aptamers and Their Significant Role in Cancer Therapy and Diagnosis.

Authors:  Joy Sebastian Prakash; Karunanithi Rajamanickam
Journal:  Biomedicines       Date:  2015-09-01

Review 8.  G-Quadruplex-Forming Aptamers-Characteristics, Applications, and Perspectives.

Authors:  Carolina Roxo; Weronika Kotkowiak; Anna Pasternak
Journal:  Molecules       Date:  2019-10-21       Impact factor: 4.411

9.  An aptasensor for the label-free detection of thrombin based on turn-on fluorescent DNA-templated Cu/Ag nanoclusters.

Authors:  Baozhu Zhang; Chunying Wei
Journal:  RSC Adv       Date:  2020-09-24       Impact factor: 4.036

10.  Selection of DNA aptamers using atomic force microscopy.

Authors:  Yusuke Miyachi; Nobuaki Shimizu; Chiaki Ogino; Akihiko Kondo
Journal:  Nucleic Acids Res       Date:  2009-12-02       Impact factor: 16.971

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.