Literature DB >> 1673646

Echocardiographic detection of coronary artery disease during dobutamine infusion.

S G Sawada1, D S Segar, T Ryan, S E Brown, A M Dohan, R Williams, N S Fineberg, W F Armstrong, H Feigenbaum.   

Abstract

BACKGROUND: Two-dimensional echocardiography performed during dobutamine infusion has been proposed as a potentially useful method for detecting coronary artery disease. However, the safety and diagnostic value of dobutamine stress echocardiography has not been established. METHODS AND
RESULTS: In this study, echocardiograms were recorded during step-wise infusion of dobutamine to a maximum dose of 30 micrograms/kg/min in 103 patients who also underwent quantitative coronary angiography. The echocardiograms were digitally stored and displayed in a format that allowed simultaneous analysis of rest and stress images. Development of a new abnormality in regional function was used as an early end point for the dobutamine infusion. No patient had a symptomatic arrhythmia or complications from stress-induced ischemia. Significant coronary artery disease (greater than or equal to 50% diameter stenosis) was present in 35 of 55 patients who had normal echocardiograms at rest. The sensitivity and specificity of dobutamine-induced wall motion abnormalities for coronary artery disease was 89% (31 of 35) and 85% (17 of 20), respectively. The sensitivity was 81% (17 of 21) in those with one-vessel disease and 100% (14 of 14) in those with multivessel or left main disease. Forty-one of 48 patients with abnormal echocardiograms at baseline had localized rest wall motion abnormalities. Fifteen had coronary artery disease confined to regions that had abnormal rest wall motion, and 26 had disease remote from these regions. Thirteen of 15 patients (87%) without remote disease did not develop remote stress-induced abnormalities, and 21 of 26 (81%) who had remote disease developed corresponding abnormalities.
CONCLUSIONS: Echocardiography combined with dobutamine infusion is a safe and accurate method for detecting coronary artery disease and for predicting the extent of disease in those who have localized rest wall motion abnormalities.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1673646     DOI: 10.1161/01.cir.83.5.1605

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  66 in total

1.  Electromechanical interrelations during dobutamine stress in normal subjects and patients with coronary artery disease: comparison of changes in activation and inotropic state.

Authors:  A M Duncan; C A O'Sullivan; D G Gibson; M Y Henein
Journal:  Heart       Date:  2001-04       Impact factor: 5.994

2.  Noninvasive Cardiac Imaging in Chest Pain Syndromes.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1998-11       Impact factor: 2.300

3.  Diagnostic criteria for detection of postinfarction ischemia by quantitative analysis of stepwise dobutamine radionuclide ventriculography.

Authors:  L Ceriani; E Verna; L Giovanella; G Binaghi; S Garancini
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

4.  Comparison of methods of fractional area change for detection of regional left ventricular dysfunction.

Authors:  S Carstensen; U Hoest; L Kjoeller-Hansen; K Saunamäki; D Atar; H Kelbaek
Journal:  Int J Card Imaging       Date:  2000-08

5.  Detection of coronary stenoses by stress echocardiography using a previously implanted pacemaker for ventricular pacing: preliminary report of a new method.

Authors:  D Benchimol; M Mazanof; B Dubroca; H Benchimol; V Bernard; T Couffinhal; J F Dartigues; R Roudaut; X Pillois; J Bonnet
Journal:  Clin Cardiol       Date:  2000-11       Impact factor: 2.882

6.  Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

Authors:  Jose Zamorano; Violeta Sánchez; Raúl Moreno; Carlos Almería; Jose Rodrigo; Viviana Serra; Luis Azcona; Adalia Aubele; Luis Mataix; Luis Sánchez-Harguindey
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

7.  Sonovue improves endocardial border detection and variability in assessing wall motion score and ejection fraction during stress echocardiography.

Authors:  A S Brown; M Calachanis; C Evdoridis; J Hancock; S Wild; A Prasan; P Nihoyannopoulos; M J Monaghan
Journal:  Ir J Med Sci       Date:  2004 Jan-Mar       Impact factor: 1.568

8.  A meta-analytic comparison of echocardiographic stressors.

Authors:  Yoshinori Noguchi; Shizuko Nagata-Kobayashi; James E Stahl; John B Wong
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

9.  Exercise tissue Doppler echocardiography with strain rate imaging in healthy young individuals: feasibility, normal values and reproducibility.

Authors:  Björn Goebel; Raoul Arnold; Eric Koletzki; Herbert E Ulmer; Joachim Eichhorn; Martin Borggrefe; Hans R Figulla; Tudor C Poerner
Journal:  Int J Cardiovasc Imaging       Date:  2006-07-26       Impact factor: 2.357

10.  Results of dobutamine stress echocardiography in patients with syndrome X.

Authors:  L Lanzarini; M Previtali; R Fetiveau; A Poli
Journal:  Int J Card Imaging       Date:  1994-06
View more