Literature DB >> 16733227

The impact of observer and patient factors on the occurrence of digit preference for zero in blood pressure measurement in a hypertension specialty clinic: evidence for the need of continued observation.

John W Graves1, Kent R Bailey, Brandon R Grossardt, Rachel E Gullerud, Ryan A Meverden, Diane E Grill, Sheldon G Sheps.   

Abstract

BACKGROUND: Many investigators have reported unconscious over-reporting of the terminal digit zero but little literature exists on observer or patient-related factors that may predict the occurrence. This study analyzes the occurrence of zero preference in 52,827 blood pressure (BP) measurements in 8513 patients by 11 hypertension nurse specialists in the Hypertension Division at Mayo Clinic, Rochester, Minnesota.
METHODS: Data from the electronic database of the Hypertension Division from April 1997 to September 2001 were analyzed for the occurrence of zero preference. Nurse-specific zero preference was stratified on four variables: number of BPs performed, years as hypertension nurse specialist, time of day BP performed (fatigue), and nursing degree. Three patient-specific factors were analyzed: age at visit (stratified by decade), type of care (continuing versus short-term), and hypertension status.
RESULTS: We found significantly increased frequency of zero preference for all BPs with mean frequency of 31% v 20% expected (P < .0001). Individual nurse zero preference varied widely, 22.0% to 53.6% for systolic BP and 22.2% to 40.8% for diastolic BP). Continuing care patients had a higher zero preference than did short-term care patients for both systolic BP (34.5% v 30.2%; P < .0001) and diastolic BP (34.7% v 33.3%; P = .006). Zero preference was also more common at higher categories of hypertension (P < .001). Time of day, nursing degree, patient age, the number of BPs performed, years of service did not affect the occurrence of digit preference.
CONCLUSIONS: Digit preference was demonstrated and varied significantly among well-trained hypertension nurse specialists. Further studies in a larger number of observers are required.

Entities:  

Mesh:

Year:  2006        PMID: 16733227     DOI: 10.1016/j.amjhyper.2005.04.004

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  10 in total

1.  Creating a transdisciplinary research center to reduce cardiovascular health disparities in Baltimore, Maryland: lessons learned.

Authors:  Lisa A Cooper; L Ebony Boulware; Edgar R Miller; Sherita Hill Golden; Kathryn A Carson; Gary Noronha; Mary Margaret Huizinga; Debra L Roter; Hsin-Chieh Yeh; Lee R Bone; David M Levine; Felicia Hill-Briggs; Jeanne Charleston; Miyong Kim; Nae-Yuh Wang; Hanan Aboumatar; Jennifer P Halbert; Patti L Ephraim; Frederick L Brancati
Journal:  Am J Public Health       Date:  2013-09-12       Impact factor: 9.308

2.  Development of heart and respiratory rate percentile curves for hospitalized children.

Authors:  Christopher P Bonafide; Patrick W Brady; Ron Keren; Patrick H Conway; Keith Marsolo; Carrie Daymont
Journal:  Pediatrics       Date:  2013-03-11       Impact factor: 7.124

3.  Novel use of Kaplan-Meier methods to explain age and gender differences in hypertension control rates.

Authors:  Kent R Bailey; Brandon R Grossardt; John W Graves
Journal:  Hypertension       Date:  2008-03-10       Impact factor: 10.190

4.  End digit preference in blood pressure measurement in a hypertension specialty clinic in southwest Nigeria.

Authors:  O E Ayodele; E O Sanya; O O Okunola; A A Akintunde
Journal:  Cardiovasc J Afr       Date:  2012-03       Impact factor: 1.167

Review 5.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

6.  A comparative study of automated blood pressure device and mercury-free LED blood pressure device using Lin's concordance correlation coefficient and other validity measures in Indian population.

Authors:  Shashi B Singh; Dewesh Kumar; Vivek Kashyap; Surendra Singh
Journal:  J Family Med Prim Care       Date:  2020-03-26

7.  Impact of terminal digit preference by family physicians and sphygmomanometer calibration errors on blood pressure value: implication for hypertension screening.

Authors:  Theophile Niyonsenga; Alain Vanasse; Josiane Courteau; Lyne Cloutier
Journal:  J Clin Hypertens (Greenwich)       Date:  2008-05       Impact factor: 3.738

8.  Digit Preference in Office Blood Pressure Measurements, United States 2015-2019.

Authors:  Kathryn E Foti; Lawrence J Appel; Kunihiro Matsushita; Josef Coresh; G Caleb Alexander; Elizabeth Selvin
Journal:  Am J Hypertens       Date:  2021-05-22       Impact factor: 2.689

9.  Manual or automated sphygmomanometer? A historical cohort to quantify measurement bias in blood pressure recording.

Authors:  Arash A Nargesi; Zaniar Ghazizadeh; Mehrdad Larry; Afsaneh Morteza; Firuzeh Heidari; Firuzeh Asgarani; Alireza Esteghamati; Kazem Mohammad; Manouchehr Nakhjavani
Journal:  J Clin Hypertens (Greenwich)       Date:  2014-09-08       Impact factor: 3.738

10.  Effects of Sachet Water Consumption on Exposure to Microbe-Contaminated Drinking Water: Household Survey Evidence from Ghana.

Authors:  Jim Wright; Mawuli Dzodzomenyo; Nicola A Wardrop; Richard Johnston; Allan Hill; Genevieve Aryeetey; Richard Adanu
Journal:  Int J Environ Res Public Health       Date:  2016-03-09       Impact factor: 3.390

  10 in total