Simulation and experimental observation of contact conditions between stents and artery models.

Kazuto Takashima1, Takayuki Kitou, Koji Mori, Ken Ikeuchi.   

Abstract

Treatment of coronary artery stenosis with percutaneous coronary angioplasty and stenting is sometimes complicated by neointimal hyperplasia, possibly due to interaction of the stent with the arterial wall within a specific contact area. Therefore, we characterized the stress distribution at the contacts between the stent and the artery using mathematical and experimental modeling (an arterial cylinder model with a tube-like structure and an arterial stenosis model, consisting of a tube and plaque portion) and two kinds of link stents with different numbers of cells and links. First, the contact condition was investigated using a finite element method (FEM). Second, experimental visualization of the contact area between the stent and the artery models was performed. Comparison of the experimental results with the FEM analysis revealed that the contact area between the stent (with a high number of cells and links) and the artery model was distributed over the total surface of the stent. Further, values obtained from the experimental distribution and the calculated distribution were similar. These data indicate that experimental modeling and FEM analysis are useful methods for analyzing the relationship between stent structure and stent/wall stress distributions and may help guide the design of new stents.

Entities:  

Mesh:

Year:  2006        PMID: 16731021     DOI: 10.1016/j.medengphy.2006.04.003

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Surgical stent planning: simulation parameter study for models based on DICOM standards.

Authors:  S Scherer; T Treichel; N Ritter; G Triebel; W G Drossel; O Burgert
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-07-22       Impact factor: 2.924

2.  Fatigue life analysis and experimental verification of coronary stent.

Authors:  Jianjun Li; Qiyi Luo; Zhiyong Xie; Yu Li; Yanjun Zeng
Journal:  Heart Vessels       Date:  2010-07-31       Impact factor: 2.037

3.  Toward improved accuracy in shear wave elastography of arteries through controlling the arterial response to ultrasound perturbation in-silico and in phantoms.

Authors:  Nicholas R Hugenberg; Tuhin Roy; Hadiya Harrigan; Margherita Capriotti; Hyoung-Ki Lee; Murthy Guddati; James F Greenleaf; Matthew W Urban; Wilkins Aquino
Journal:  Phys Med Biol       Date:  2021-11-26       Impact factor: 3.609

4.  On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests.

Authors:  Markus A Geith; Krzysztof Swidergal; Bernd Hochholdinger; Thomas G Schratzenstaller; Marcus Wagner; Gerhard A Holzapfel
Journal:  Int J Numer Method Biomed Eng       Date:  2019-11       Impact factor: 2.648

5.  Simulation of stent deployment in a realistic human coronary artery.

Authors:  Frank J H Gijsen; Francesco Migliavacca; Silvia Schievano; Laura Socci; Lorenza Petrini; Attila Thury; Jolanda J Wentzel; Anton F W van der Steen; Patrick W S Serruys; Gabriele Dubini
Journal:  Biomed Eng Online       Date:  2008-08-06       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.