Literature DB >> 16729867

Integration between the tele-cardiology unit and the central laboratory: methodological and clinical evaluation of point-of-care testing cardiac marker in the ambulance.

Francesca Di Serio1, Roberto Lovero, Massimo Leone, Rosalia De Sario, Vincenzo Ruggieri, Lucia Varraso, Nicola Pansini.   

Abstract

The aim of this study was to identify patients with myocardial necrosis in pre-hospital phase during transport by ambulance, without ST-segment elevation (NSTE) on the ambulance ECG. The analytical performance of the i-STAT troponin I (cTnI) method was assessed. A total of 53 NSTE ambulance ECG patients admitted to hospital were followed. The ambulance had experimental software able to receive data from the i-STAT device and transmit it to a protected address and server. cTnI mean values from 2.0 to 34 microg/L showed a total CV of 3.0-5.6%. The detection limit was 0.016 microg/L. A mean cTnI concentration of 0.09 microg/L was associated with a CV of 8.0% (decision limit). The i-STAT cTnI method was linear for concentrations from 0 to 35 microg/L. There was no effect (p<0.05) of interfering substances. For point-of-care testing (POCT), cTnI was >0.09 microg/L in 20 AMI patients (91%). The median ambulance turnaround time (TAT) was 12 min and median hospital TAT was 40 min, a difference of 28 min. The high sensitivity of the i-STAT cTnI method integrated with tele-medicine procedures could play an important role in the management of acute coronary syndrome patients related to the pre-hospital phase (early diagnosis and treatment in the ambulance). These approaches may allow improvements in patient outcomes and continuous monitoring of the POCT network in the central laboratory, thus meeting quality requirements.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16729867     DOI: 10.1515/CCLM.2006.125

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  10 in total

1.  Preconcentration and detection of the phosphorylated forms of cardiac troponin I in a cascade microchip by cationic isotachophoresis.

Authors:  Danny Bottenus; Mohammad Robiul Hossan; Yexin Ouyang; Wen-Ji Dong; Prashanta Dutta; Cornelius F Ivory
Journal:  Lab Chip       Date:  2011-09-21       Impact factor: 6.799

Review 2.  [Point-of-care testing in preclinical emergency medicine].

Authors:  M Möckel; J Searle
Journal:  Med Klin Intensivmed Notfmed       Date:  2014-03-13       Impact factor: 0.840

3.  10,000-fold concentration increase of the biomarker cardiac troponin I in a reducing union microfluidic chip using cationic isotachophoresis.

Authors:  Danny Bottenus; Talukder Zaki Jubery; Yexin Ouyang; Wen-Ji Dong; Prashanta Dutta; Cornelius F Ivory
Journal:  Lab Chip       Date:  2011-03-07       Impact factor: 6.799

4.  10,000-fold concentration increase in proteins in a cascade microchip using anionic ITP by a 3-D numerical simulation with experimental results.

Authors:  Danny Bottenus; Talukder Zaki Jubery; Prashanta Dutta; Cornelius F Ivory
Journal:  Electrophoresis       Date:  2011-02-10       Impact factor: 3.535

5.  Point-of-Care Testing at the Disaster-Emergency-Critical Care Interface.

Authors:  Nam K Tran; Zachary Godwin; Jennifer Bockhold
Journal:  Point Care       Date:  2012-12-01

6.  Quantitative analysis of serum procollagen type I C-terminal propeptide by immunoassay on microchip.

Authors:  Shouki Yatsushiro; Rie Akamine; Shohei Yamamura; Mami Hino; Kazuaki Kajimoto; Kaori Abe; Hiroko Abe; Jun-ichi Kido; Masato Tanaka; Yasuo Shinohara; Yoshinobu Baba; Toshihiko Ooie; Masatoshi Kataoka
Journal:  PLoS One       Date:  2011-04-13       Impact factor: 3.240

Review 7.  Mapping turnaround times (TAT) to a generic timeline: a systematic review of TAT definitions in clinical domains.

Authors:  Bernhard Breil; Fleur Fritz; Volker Thiemann; Martin Dugas
Journal:  BMC Med Inform Decis Mak       Date:  2011-05-24       Impact factor: 2.796

8.  Community paramedic point of care testing: validity and usability of two commercially available devices.

Authors:  Ian E Blanchard; Ryan Kozicky; Dana Dalgarno; Justin Simms; Stacy Goulder; Tyler S Williamson; Susan Biesbroek; Lenore Page; Karen Leaman; Suzanne Snozyk; Lyle Redman; Keith Spackman; Christopher J Doig; Eddy S Lang; Gerald Lazarenko
Journal:  BMC Emerg Med       Date:  2019-05-02

9.  A Retrospective Review of Patient Records and Factors Associated with Decisions Made by Community Nurse-Paramedics' in Finland.

Authors:  Tuija Rasku; Mika Helminen; Marja Kaunonen; Elizabeth Thyer; Eija Paavilainen; Katja Joronen
Journal:  Nurs Rep       Date:  2021-08-31

10.  Simultaneous immunoassay analysis of plasma IL-6 and TNF-α on a microchip.

Authors:  Kaori Abe; Yoshiko Hashimoto; Shouki Yatsushiro; Shohei Yamamura; Mika Bando; Yuka Hiroshima; Jun-ichi Kido; Masato Tanaka; Yasuo Shinohara; Toshihiko Ooie; Yoshinobu Baba; Masatoshi Kataoka
Journal:  PLoS One       Date:  2013-01-09       Impact factor: 3.240

  10 in total