Literature DB >> 16725294

Magnetic resonance-guided focused ultrasound surgery (MRgFUS): ablation of liver tissue in a porcine model.

Doron Kopelman1, Yael Inbar, Arik Hanannel, David Freundlich, David Castel, Azriel Perel, Adrian Greenfeld, Tal Salamon, Merab Sareli, Adrian Valeanu, Moshe Papa.   

Abstract

BACKGROUND: Liver surgery is technically demanding and is considered a major procedure with relatively high morbidity rates. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) uses focused ultrasonic energy to create a heat coagulation lesion, which can be achieved in a totally controlled, very accurate manner (<1 mm). The aim of this study was to evaluate the safety and accuracy of non-invasive focal ablation of liver tissue achieved by consecutive MRgFUS sonications.
MATERIALS AND METHODS: Six MRgFUS procedures were performed in five pigs under general anesthesia, with the ExAblate 2000 system (InSightec, Israel). Real-time imaging and temperature mapping (Signa Twinspeed 1.5T, GEHC, USA) enabled the immediate evaluation of the results of each sonication. Different foci were chosen within the liver. These mock lesions were ablated by several sonications, each of them performed during 20-30 s of apnea. Between sonications, the pigs were normally ventilated. The pigs were sacrificed 3-21 days after the procedure and their livers were examined.
RESULTS: The MRgFUS created complete tissue destruction of mock lesions in different areas of the pig's liver. The lesion sizes in each animal varied according to the number of sonications used and the extent of overlap between adjacent sonications. The lesion ranged in size from 1.5 cm x 1.5 cm x 2.0 cm to 5.5 cm x 4.5 cm x 2.0 cm. There was no morbidity.
CONCLUSIONS: MRgFUS under general anesthesia is a safe, completely non-invasive technology for the ablation of liver tissue. Liver tissue can be ablated in a very accurate manner, based on the pre-treatment planning on the MR images. The MR imaging characteristics, including real-time temperature mapping, enable real-time control of every step of the ablation process. Mechanical ventilation with intermittent periods of apnea is a technique that overcomes the problem of the respiratory movements of the liver.

Entities:  

Mesh:

Year:  2006        PMID: 16725294     DOI: 10.1016/j.ejrad.2006.04.008

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

Review 1.  MRI-guided laparoscopic and robotic surgery for malignancies.

Authors:  Makoto Hashizume
Journal:  Int J Clin Oncol       Date:  2007-04-27       Impact factor: 3.402

2.  Adaptive 4D MR imaging using navigator-based respiratory signal for MRI-guided therapy.

Authors:  Junichi Tokuda; Shigehiro Morikawa; Hasnine A Haque; Tetsuji Tsukamoto; Kiyoshi Matsumiya; Hongen Liao; Ken Masamune; Takeyoshi Dohi
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

3.  Transcostal high-intensity-focused ultrasound: ex vivo adaptive focusing feasibility study.

Authors:  J-F Aubry; M Pernot; F Marquet; M Tanter; M Fink
Journal:  Phys Med Biol       Date:  2008-05-12       Impact factor: 3.609

4.  Can we ablate liver lesions close to large portal and hepatic veins with MR-guided HIFU? An experimental study in a porcine model.

Authors:  Ulrik Carling; Leonid Barkhatov; Henrik M Reims; Tryggve Storås; Frederic Courivaud; Airazat M Kazaryan; Per Steinar Halvorsen; Eric Dorenberg; Bjørn Edwin; Per Kristian Hol
Journal:  Eur Radiol       Date:  2019-02-08       Impact factor: 5.315

Review 5.  Thresholds for thermal damage to normal tissues: an update.

Authors:  Pavel S Yarmolenko; Eui Jung Moon; Chelsea Landon; Ashley Manzoor; Daryl W Hochman; Benjamin L Viglianti; Mark W Dewhirst
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

6.  Pediatric Sarcomas Are Targetable by MR-Guided High Intensity Focused Ultrasound (MR-HIFU): Anatomical Distribution and Radiological Characteristics.

Authors:  Jenny Shim; Robert M Staruch; Korgun Koral; Xian-Jin Xie; Rajiv Chopra; Theodore W Laetsch
Journal:  Pediatr Blood Cancer       Date:  2016-05-19       Impact factor: 3.167

7.  Calibration and Evaluation of Ultrasound Thermography Using Infrared Imaging.

Authors:  Yi-Sing Hsiao; Cheri X Deng
Journal:  Ultrasound Med Biol       Date:  2015-11-05       Impact factor: 2.998

Review 8.  Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours.

Authors:  J W Wijlemans; L W Bartels; R Deckers; M Ries; W P Th M Mali; C T W Moonen; M A A J van den Bosch
Journal:  Cancer Imaging       Date:  2012-09-28       Impact factor: 3.909

9.  An Ultrasound Image-Based Dynamic Fusion Modeling Method for Predicting the Quantitative Impact of In Vivo Liver Motion on Intraoperative HIFU Therapies: Investigations in a Porcine Model.

Authors:  W Apoutou N'Djin; Jean-Yves Chapelon; David Melodelima
Journal:  PLoS One       Date:  2015-09-23       Impact factor: 3.240

10.  Minimally invasive image-guided therapy for inoperable hepatocellular carcinoma: What is the evidence today?

Authors:  Beatrijs A Seinstra; Otto M van Delden; Karel J van Erpecum; Richard van Hillegersberg; Willem P Th M Mali; Maurice A A J van den Bosch
Journal:  Insights Imaging       Date:  2010-06-01
View more