Literature DB >> 16725133

Evaluation of a fluorescent polarization immunoassay for whole blood everolimus determination using samples from renal transplant recipients.

Paul Salm1, Christopher Warnholtz, Jared Boyd, Lili Arabshahi, Peter Marbach, Paul J Taylor.   

Abstract

OBJECTIVES: This study compared the performance of a fluorescent polarization immunoassay (FPIA) against HPLC-tandem mass spectrometry (HPLC-MS) for the measurement of everolimus in renal transplant recipients. DESIGN AND METHODS: A total of 333 pre-dose samples from 45 renal transplant patients were analyzed by FPIA and HPLC-MS.
RESULTS: The inter-batch inaccuracy and precision of the FPIA for control samples were <or=6% and <or=13.0%, respectively (n = 17). The comparison of patient results yielded the Deming regression equation FPIA = 1.19 x HPLC-MS + 0.51. The mean bias was 24.4% (95% CI: -3.0 to 54.2%, range: -30.1% to 79.4%).
CONCLUSIONS: The FPIA had acceptable analytical performance during the study but compared to HPLC-MS overestimated everolimus in patient samples. This overestimation is probably due to calibration differences between the methods and cross-reactivity of the FPIA antibody with everolimus metabolites. The clinical importance of the observed overestimation by FPIA requires further investigation.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16725133     DOI: 10.1016/j.clinbiochem.2006.03.019

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  5 in total

1.  Comparison between a liquid chromatography-tandem mass spectrometry assay and a fluorescent polarization immunoassay to measure whole blood everolimus concentration in heart and renal transplantations.

Authors:  Eric Dailly; G Deslandes; M Hourmant; T Petit; C Renaud; M Treilhaud; P Jolliet
Journal:  J Clin Lab Anal       Date:  2008       Impact factor: 2.352

Review 2.  Therapeutic drug monitoring in pediatric renal transplantation.

Authors:  Lutz T Weber
Journal:  Pediatr Nephrol       Date:  2014-04-25       Impact factor: 3.714

3.  Long-term cross-validation of everolimus therapeutic drug monitoring assays: the Zortracker study.

Authors:  Björn Schniedewind; Stefanie Niederlechner; Jeffrey L Galinkin; Kamisha L Johnson-Davis; Uwe Christians; Eric J Meyer
Journal:  Ther Drug Monit       Date:  2015-06       Impact factor: 3.681

4.  A rapid HPLC-MS/MS method for the simultaneous quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human blood samples.

Authors:  Christoph Seger; Karin Tentschert; Wolfgang Stöggl; Andrea Griesmacher; Steven L Ramsay
Journal:  Nat Protoc       Date:  2009       Impact factor: 13.491

5.  Prevention of acute graft-versus-host disease by magnetic nanoparticles of Fe₃O₄ combined with cyclosporin A in murine models.

Authors:  Jian Cheng; Ying Zhou; Baoan Chen; Jun Wang; Guohua Xia; Nan Jin; Jiahua Ding; Chong Gao; Gouming Chen; Yushan Miao; Weilan Li; Ziling Liu; Xuemei Wang
Journal:  Int J Nanomedicine       Date:  2011-10-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.