Literature DB >> 16721463

Shear bond strength of acetone-based one-bottle adhesive systems.

Guilherme Carpena Lopes1, Paula C Cardoso, Luiz Clovis Cardoso Vieira, Luiz N Baratieri, Karina Rampinelli, Gisele Costa.   

Abstract

The aim of this study was to assess the shear bond strength of four acetone-based one-bottle adhesive systems to enamel and dentin, and compare to that of an ethanol-based system used as control. Fifty human molars were bisected mesiodistally and the buccal and lingual surfaces were embedded in acrylic resin using PVC cylinders. The buccal surfaces were ground to obtain flat dentin surfaces, while the lingual surfaces were ground to obtain flat enamel surfaces. All specimens were polished up to 600-grit sandpapers and randomly assigned to 5 groups (n=20; 10 dentin specimens and 10 enamel specimens), according to the adhesive system used: One-Step (Bisco); Gluma One Bond (Heraeus Kulzer); Solobond M (Voco); TenureQuik w/F (Den-Mat) and OptiBond Solo Plus (Kerr) (control). Each adhesive system was applied according to the manufacturers' instructions. The respective proprietary hybrid composite was applied in a gelatin capsule (d=4.3 mm) and light-cured for 40 s. The specimens were tested in shear strength with an Instron machine at a crosshead speed of 5 mm/min. Bond strengths means were analyzed statistically by one-way ANOVA and Duncan's post-hoc (p< or =0.05). Shear bond strength means (MPa) (+/-SD) to enamel and dentin were: Enamel: One-Step=11.3(+/-4.9); Gluma One Bond=16.3(+/-10.1); Solobond M=18.9(+/-4.5); TenureQuik w/F=18.7(+/-4.5) and OptiBond Solo Plus=16.4(+/-3.9); Dentin: One-Step=6.4(+/-2.8); Gluma One Bond=3.0(+/-3.4); Solobond M=10.6(+/-4.9); TenureQuik w/F=7.8(+/-3.9) and OptiBond Solo Plus=15.1(+/-8.9). In enamel, the adhesive systems had statistically similar bond strengths to each other (p>0.05). However, the ethanol-based system (OptiBond Solo Plus) showed significantly higher bond strength to dentin than the acetone-based systems (p< or =0.0001). In conclusion, the solvent type (acetone or ethanol) had no influence on enamel bond strength, but had great influence on dentin bonding, which should be taken into account when choosing the adhesive system.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16721463     DOI: 10.1590/s0103-64402006000100009

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  9 in total

1.  In vitro evaluation of shear bond strength of nanocomposites to dentin.

Authors:  Swati Gupta; Vinay Kumar Vellanki; Vikram K Shetty; Sudhanshu Kushwah; Geeta Goyal; S M Sharath Chandra
Journal:  J Clin Diagn Res       Date:  2015-01-01

2.  Evaluation of the Shear Bond Strength of Composite Resin to Wet and Dry Enamel Using Dentin Bonding Agents Containing Various Solvents.

Authors:  Carounanidy Usha; Sathyanarayanan Ramarao; Bindu Meera John; Praveen Rajesh; S Swatha
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  Effects of Rinsing Water Temperature and Preheated Composites on Microleakage of Composite Restorations with Two Bonding Agents.

Authors:  Mohammad Reza Malekipour; Mehrdad Barekatain; Farzaneh Shirani; Samaneh Alaei
Journal:  Front Dent       Date:  2022-01-04

4.  A comparative evaluation of the bonding efficacy of two-step vs all-in-one bonding agents - An in-vitro study.

Authors:  Viresh Chopra; Himanshu Sharma; S Datta Prasad
Journal:  J Conserv Dent       Date:  2009-07

5.  Comparative evaluation of the enamel bond strength of 'etch-and-rinse' and 'all-in-one' bonding agents on cut and uncut enamel surfaces.

Authors:  Deepu Patil; Kiran Prabhakar Singbal; Sharad Kamat
Journal:  J Conserv Dent       Date:  2011-04

6.  Shear bond strengths of two dentin bonding agents with two desensitizers: An in vitro study.

Authors:  N Ravikumar; P Shankar; R Indira
Journal:  J Conserv Dent       Date:  2011-07

7.  Influence of air abrasion and sonic technique on microtensile bond strength of one-step self-etch adhesive on human dentin.

Authors:  Baraba Anja; Dukić Walter; Chieffi Nicoletta; Ferrari Marco; Sonja Pezelj Ribarić; Miletić Ivana
Journal:  ScientificWorldJournal       Date:  2015-03-23

8.  The effect of acrylate-based dental adhesive solvent content on microleakage in composite restorations.

Authors:  Mahboubeh Mirzakhani; Sayed Mostafa Mousavinasab; Mohammad Atai
Journal:  Dent Res J (Isfahan)       Date:  2016 Nov-Dec

9.  Solvent type influences bond strength to air or blot-dried dentin.

Authors:  Özgür Irmak; İsmail Hakkı Baltacıoğlu; Nuran Ulusoy; Yıldırım Hakan Bağış
Journal:  BMC Oral Health       Date:  2016-08-22       Impact factor: 2.757

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.