Literature DB >> 16715190

Is the coronary flow velocity reserve improvement after aortic valve replacement for aortic stenosis transient? Results of a 3-year follow-up.

Attila Nemes1, Tamás Forster, Zsolt Kovács, Miklós Csanády.   

Abstract

The coronary flow velocity reserve (CFR) is decreased in patients with aortic valve stenosis (AS). The aim of the present prospective study was to examine the CFR in AS patients with normal epicardial coronary arteries during a 3-year follow-up of aortic valve replacement (AVR). A total of 30 AS patients (17 women and 13 men) were enrolled in this prospective follow-up study; they all had a normal coronary angiogram and underwent dipyridamole stress transesophageal echocardiography (STEE) for CFR measurement before AVR. Nine of them participated in this 3-year follow-up study, and all patients were examined 16 months and 3 years after AVR by STEE. The CFR of AS patients was decreased before AVR. Different extents of diastolic coronary flow velocity reduction (resting and posthyperaemic) were observed resulting in a significant CFR improvement, despite the low number of patients during the 16-month follow-up. A further posthyperaemic flow velocity reduction was demonstrated after the 3-year follow-up, resulting in a significant CFR impairment. The CFR decreased in 5 cases, but remained practically unchanged in 3 after the first CFR measurement; only the CFR of 1 patient improved minimally. The main finding of the current study is that the CFR improvement 16 months after AVR, which paralleled the regression of the left ventricular hypertrophy, was found to be transient. Coronary flow velocity reserve impairment was demonstrated after the long-term (3-year) follow-up in most of the patients, which could not be explained by extravascular compressive forces.

Entities:  

Mesh:

Year:  2006        PMID: 16715190     DOI: 10.1007/s00380-005-0883-z

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  23 in total

1.  Coronary flow reserve improves after aortic valve replacement for aortic stenosis: an adenosine transthoracic echocardiography study.

Authors:  D J Hildick-Smith; L M Shapiro
Journal:  J Am Coll Cardiol       Date:  2000-11-15       Impact factor: 24.094

2.  Coronary reserve in patients with aortic valve disease before and after successful aortic valve replacement.

Authors:  F R Eberli; M Ritter; J Schwitter; A Bortone; J Schneider; O M Hess; H P Krayenbuehl
Journal:  Eur Heart J       Date:  1991-02       Impact factor: 29.983

3.  How can coronary flow reserve be altered by severe aortic stenosis?

Authors:  Attila Nemes; Tamás Forster; Albert Varga; Andrea Vass; Angela Borthaiser; Attila Pálinkás; Miklós Csanády
Journal:  Echocardiography       Date:  2002-11       Impact factor: 1.724

4.  Comparison of intracoronary Doppler guide wire and transesophageal echocardiography in measurement of flow velocity and coronary flow reserve in the left anterior descending coronary artery.

Authors:  S Gadallah; K B Thaker; D Kawanishi; A Mehra; S Lau; M Rashtian; A N Chandraratna
Journal:  Am Heart J       Date:  1998-01       Impact factor: 4.749

5.  Angina pectoris in patients with aortic stenosis and normal coronary arteries. Mechanisms and pathophysiological concepts.

Authors:  B K Julius; M Spillmann; G Vassalli; B Villari; F R Eberli; O M Hess
Journal:  Circulation       Date:  1997-02-18       Impact factor: 29.690

6.  The effect of aortic valve replacement on coronary flow reserve in patients with a normal coronary angiogram.

Authors:  Attila Nemes; Tamás Forster; Zsolt Kovács; Attila Thury; Imre Ungi; Miklós Csanády
Journal:  Herz       Date:  2002-12       Impact factor: 1.443

7.  Determination of coronary reserve in patients with supravalvular aortic stenosis.

Authors:  D B Doty; C L Eastham; L F Hiratzka; C B Wright; M L Marcus
Journal:  Circulation       Date:  1982-08       Impact factor: 29.690

8.  [Mechanisms of impaired coronary flow reserve in patients with aortic stenosis: transthoracic Doppler echocardiographic study].

Authors:  Teruyoshi Kume; Takashi Akasaka; Takahiro Kawamoto; Nozomi Watanabe; Hidetoshi Yoshitani; Maki Akiyama; Yuji Koyama; Yoji Neishi; Nozomi Wada; Kiyoshi Yoshida
Journal:  J Cardiol       Date:  2004-04       Impact factor: 3.159

9.  Exclusion of coronary artery disease by exercise thallium-201 tomography in patients with aortic valve stenosis.

Authors:  M Kupari; K S Virtanen; H Turto; M Viitasalo; M Mänttäri; M Lindroos; E Koskela; H Leinonen; S Pohjola-Sintonen; J Heikkilä
Journal:  Am J Cardiol       Date:  1992-09-01       Impact factor: 2.778

10.  [Transient myocardial ischemia in hypertensive patients].

Authors:  S Scheler; W Motz; B E Strauer
Journal:  Z Kardiol       Date:  1989-03
View more
  5 in total

1.  Prognostic value of coronary flow reserve and aortic distensibility indices in patients with suspected coronary artery disease.

Authors:  Attila Nemes; Tamás Forster; Marcel L Geleijnse; Osama I I Soliman; Folkert J Ten Cate; Miklós Csanády
Journal:  Heart Vessels       Date:  2008-05-17       Impact factor: 2.037

2.  Left ventricular mass regression following implantation of MIRA bileaflet valves in patients with severe aortic stenosis.

Authors:  Stefan Toggweiler; Michel Zuber; Katharina Gerber; Reinhard Schläpfer; Paul Erne; Peter Stulz
Journal:  Heart Vessels       Date:  2009-01-23       Impact factor: 2.037

3.  Why Can Fractional Flow Reserve Decrease After Transcatheter Aortic Valve Implantation?

Authors:  Jo M Zelis; Pim A L Tonino; Nils P Johnson
Journal:  J Am Heart Assoc       Date:  2020-02-27       Impact factor: 5.501

4.  Microcirculatory Function in Nonhypertrophic and Hypertrophic Myocardium in Patients With Aortic Valve Stenosis.

Authors:  Muhammad Sabbah; Niels Thue Olsen; Mikko Minkkinen; Lene Holmvang; Hans-Henrik Tilsted; Frants Pedersen; Francis R Joshi; Kiril Ahtarovski; Rikke Sørensen; Jesper James Linde; Lars Søndergaard; Nico Pijls; Jacob Lønborg; Thomas Engstrøm
Journal:  J Am Heart Assoc       Date:  2022-04-26       Impact factor: 6.106

5.  Simultaneous echocardiographic evaluation of coronary flow velocity reserve and aortic distensibility indices in hypertension.

Authors:  Attila Nemes; Tamás Forster; Miklós Csanády
Journal:  Heart Vessels       Date:  2007-03-23       Impact factor: 1.814

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.