Literature DB >> 16713841

Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study.

Shukuki Koh1, Randal P Morris, Rita M Patterson, J Patrick Kearney, William L Buford, Steven F Viegas.   

Abstract

PURPOSE: To compare the biomechanical properties of 10 volar plate-fixation designs in 2 fracture models (dorsal wedge osteotomy, segmental resection osteotomy models).
METHODS: Forty-eight radiuses were used in this study including 8 pairs. In 40 specimens a 15-mm dorsally based wedge osteotomy was performed and the volar cortex was fractured manually. They were arranged into 10 fixation groups with 5 different fixation designs (test 1). In the contralateral specimens of 8 paired radiuses a 10-mm segment of bone was excised (test 2). Four of the 10 fixation systems were chosen for these specimens. Cadaver hands and the proximal radiuses were potted in polymethylmethacrylate and tested with a servohydraulic materials testing machine with 300 N of axial compression load at 1 N/s initially and after each 1,000 cycles up to 5,000 cycles. After cyclic loading the specimens were loaded to failure in axial compression at 2 mm/min. The stiffness, failure peak load, and failure mode of each specimen were recorded.
RESULTS: In test 1 in the wedge osteotomy specimens the T plate was the stiffest and the Synthes titanium plate was the least stiff; however, all specimens completed the 5,000 cycles of loading with no failures. There was no significant difference between the 10 fixation groups in failure peak load and only 7 of 40 failed at the distal portion of the hardware in the final load to failure testing. In test 2 the resection osteotomy specimens were less stiff and failed at a lower failure peak load compared with the wedge osteotomy specimens. Failure at the distal portion of the fixation system was seen in 7 of 8 specimens; nonlocking screws loosened and tines compressed the surrounding bone, resulting in tine-hole enlargement.
CONCLUSIONS: All of the plate-fixation systems delivered sufficient stability to permit the simulated postoperative regimen of 1 week of immobilization followed by 5 weeks of early mobilization until expected union at 6 weeks after surgery. Based on these results a preferable volar fixation system would appear to benefit from the following: (1) sufficient plate strength to support the distal fragment from the volar side, (2) a locking system with sufficient strength to remain locked during the healing process, and (3) a distal design that does not affect the bone adversely. The anatomic reduction of the volar cortex in the wedge osteotomy specimens added stability to the construct.

Entities:  

Mesh:

Year:  2006        PMID: 16713841     DOI: 10.1016/j.jhsa.2006.02.015

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  20 in total

1.  Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.

Authors:  Daniel Marsland; Chris M Hobbs; Philip S Sauvé
Journal:  Hand (N Y)       Date:  2014-12

Review 2.  Treatment of distal radius fractures with locking plates: an update.

Authors:  Francois Loisel; Hugo Kielwasser; Grégoire Faivre; Thomas Rondot; Séverin Rochet; Antoine Adam; Pauline Sergent; Grégoire Leclerc; Laurent Obert; Daniel Lepage
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-07-12

3.  Early Rehabilitation of Distal Radius Fractures Stabilized by Volar Locking Plate: A Prospective Randomized Pilot Study.

Authors:  Stefan Quadlbauer; Christoph Pezzei; Josef Jurkowitsch; Brigitta Kolmayr; Tina Keuchel; Daniel Simon; Thomas Hausner; Martin Leixnering
Journal:  J Wrist Surg       Date:  2016-08-05

4.  Damage in a Distal Radius Fracture Model Treated With Locked Volar Plating After Simulated Postoperative Loading.

Authors:  Christina Salas; Justin A Brantley; James Clark; Mahmoud Reda Taha; Orrin B Myers; Deana Mercer
Journal:  J Hand Surg Am       Date:  2018-02-06       Impact factor: 2.230

5.  Dacron--silicone prosthesis for the metacarpophalangeal and interphalangeal joints.

Authors:  J J Niebauer; R M Landry
Journal:  Hand       Date:  1971-03

6.  Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization.

Authors:  André Duprat; Juan José Hidalgo Diaz; Paul Vernet; Stéphanie Gouzou; Sybille Facca; Yuka Igeta; Philippe Liverneaux
Journal:  J Wrist Surg       Date:  2018-01-16

7.  Management of Unstable Distal Radius Fractures: A Survey of Hand Surgeons.

Authors:  Ara A Salibian; Karl C Bruckman; Jonathan M Bekisz; Joshua Mirrer; Vishal D Thanik; Jacques H Hacquebord
Journal:  J Wrist Surg       Date:  2018-11-16

8.  Corrective osteotomy for deformity of the distal radius using a volar locking plate.

Authors:  Brett Peterson; Varun Gajendran; Robert M Szabo
Journal:  Hand (N Y)       Date:  2007-08-10

9.  Biomechanical comparison of different volar fracture fixation plates for distal radius fractures.

Authors:  Kareem Sobky; Todd Baldini; Kenneth Thomas; Joel Bach; Allison Williams; Jennifer Moriatis Wolf
Journal:  Hand (N Y)       Date:  2007-09-07

10.  Biomechanical evaluation of volar locking plates for distal radius fractures.

Authors:  Scott M Levin; Cory O Nelson; Jonathan D Botts; Glenn A Teplitz; Yong Kwon; Fred Serra-Hsu
Journal:  Hand (N Y)       Date:  2007-08-07
View more