Literature DB >> 16710817

Real time 3D (4D) ultrasound-guided percutaneous biopsy of solid tumours.

H Albrecht1, C Stroszczynski, R Felix, M Hünerbein.   

Abstract

PURPOSE: The aim of the current study was to investigate the feasibility of real-time 3D (4D) ultrasound-guided biopsy.
MATERIALS AND METHODS: Between 2003 and 2005, 53 patients with suspicious lymph nodes or solid tumours underwent 4D ultrasound-guided core needle biopsy using a 4D US-System (Voluson 730, GE/Kretztechnik, Austria). The results were documented prospectively and compared to a matched series of 53 conventional 2D ultrasound-guided core biopsies.
RESULTS: 4D ultrasound-guided biopsy can be performed using multiplanar views or a combination of cross-sectional and rendered images. Assessment of additional 3D images during the biopsy procedure was helpful in 34 % of the cases. In the differentiation of malignant and benign lesions, 4D ultrasound guided biopsy yielded 35 true-positive results, 12 true-negative results and 5 false-negative results. The sensitivity and specificity for the diagnosis of malignancy was 87.5 % and 94.4 %, respectively (control group: 89.5 % and 94.4 %). There was one case of insufficient tissue sampling in the 4D targeting group and 2 cases in the control group. No complications were observed related to the biopsy procedure.
CONCLUSIONS: 4D ultrasound-guided biopsy is feasible and can improve visualisation of biopsy procedures by multiplanar display or 3D rendering. Although the accuracy is comparable to that of conventional 2D biopsy, this technique may be helpful for biopsy of lesions with close relation to relevant anatomical structures.

Entities:  

Mesh:

Year:  2006        PMID: 16710817     DOI: 10.1055/s-2006-926804

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  6 in total

1.  [Transcutaneous ultrasound].

Authors:  M Hünerbein; S S Chopra; P M Schlag
Journal:  Chirurg       Date:  2007-05       Impact factor: 0.955

2.  Feasibility of navigated resection of liver tumors using multiplanar visualization of intraoperative 3-dimensional ultrasound data.

Authors:  Siegfried Beller; Michael Hünerbein; Sebastian Eulenstein; Thomas Lange; Peter M Schlag
Journal:  Ann Surg       Date:  2007-08       Impact factor: 12.969

Review 3.  Development of technologies for placement of perineural catheters.

Authors:  Hesham Elsharkawy; Ankit Maheshwari; Ehab Farag; Edward R Mariano; Richard W Rosenquist
Journal:  J Anesth       Date:  2015-09-14       Impact factor: 2.078

4.  A 3D multi-modal intelligent intervention system using electromagnetic navigation for real-time positioning and ultrasound images: a prospective randomized controlled trial.

Authors:  Weiwei Tang; Yun Zhou; Hui Zhao; Guangshun Sun; Dawei Rong; Zhitao Li; Meng Hu; Liu Han; Xu He; Suming Zhao; Xiaoyang Chen; Zhongming Li; Hongxin Yuan; Songwang Chen; Qian Wang; Zhouxiao Li; Jianping Gu; Xuehao Wang; Jinhua Song
Journal:  Ann Transl Med       Date:  2022-06

Review 5.  Developments in musculoskeletal ultrasound and clinical applications.

Authors:  Andrea S Klauser; Philippe Peetrons
Journal:  Skeletal Radiol       Date:  2010-11       Impact factor: 2.199

6.  A standardized method for 4D ultrasound-guided peripheral nerve blockade and catheter placement.

Authors:  N J Clendenen; C B Robards; S R Clendenen
Journal:  Biomed Res Int       Date:  2014-01-19       Impact factor: 3.411

  6 in total