Literature DB >> 16707118

Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photospray ionization tandem mass spectrometry.

Tiedong Guo1, Robert L Taylor, Ravinder J Singh, Steven J Soldin.   

Abstract

BACKGROUND: Serum steroid assays play an important role in the clinical evaluation of a number of common endocrine disorders. Among various assays, tandem mass spectrometry (MS/MS) has being increasingly applied in clinical laboratories for its high sensitivity, specificity, and simultaneous multi-analyte quantitation capability. Our first generation isotope dilution steroid profile assay by HPLC-tandem MS/MS with a C-18 column allowed for the measurement of 9 steroids in 18 min employing a sample volume of 760 ul serum. We describe our second generation steroid profile assay which allows for the quantitation of 12 steroids simultaneously employing HPLC-MS/MS and isotope dilution tandem MS in 11 min. This method requires a sample volume of 200 microl.
METHODS: An API-5000 triple-quadrupole mass spectrometer (Sciex, Concord, Canada) coupled with the PhotoSpray source and Shimadzu HPLC system (Shimadzu Scientific Instruments, Columbia, MD) was used employing isotope dilution with deuterium labeled internal standard (IS) for each analyte. Two hundred microliters of serum were deproteinized by adding 300 microl of acetonitrile containing internal standards. After centrifugation, 450 microl of supernatant were diluted with 900 microl of water and 1000 microl aliquot were injected onto a C-8 column. After a 3 min wash the valve was activated to initiate the gradient elution program which eluted the steroids. Quantitation by MRM analysis was performed both in positive ion mode for 11 analytes and in negative ion mode for aldosterone. Within-day and between-day precision, reliability and accuracy of this method were assessed by correlation with other MS/MS and immunoassay methods and by recovery study.
RESULTS: Within-day CVs were <11.5% for all analytes tested and between-day CVs ranged from 3.5% to 12.2%. The results of the comparison study yield r values ranging between 0.908 and 0.999. Recovery ranged from 90% to 110%.
CONCLUSIONS: This method can simultaneously measure 12 steroids in serum within 11 min with minimal sample preparation. It can be routinely employed in a clinical environment and is attractive because of its simplicity in sample processing and high throughput.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16707118     DOI: 10.1016/j.cca.2006.03.034

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  52 in total

1.  Administration of dehydroepiandrosterone (DHEA) enhances visual-spatial performance in postmenopausal women.

Authors:  Bethany Stangl; Elliot Hirshman; Joseph Verbalis
Journal:  Behav Neurosci       Date:  2011-10       Impact factor: 1.912

2.  An improved micro-method for the measurement of steroid profiles by APPI-LC-MS/MS and its use in assessing diurnal effects on steroid concentrations and optimizing the diagnosis and treatment of adrenal insufficiency and CAH.

Authors:  Brian R Stolze; Verena Gounden; Jianghong Gu; Elizabeth A Elliott; Likhona S Masika; Brent S Abel; Deborah P Merke; Monica C Skarulis; Steven J Soldin
Journal:  J Steroid Biochem Mol Biol       Date:  2015-12-22       Impact factor: 4.292

3.  Determination of cortisol production rates with contemporary liquid chromatography-mass spectrometry to measure cortisol-d(3) dilution after infusion of deuterated tracer.

Authors:  Bethany J Klopfenstein; Jonathan Q Purnell; David D Brandon; Lorne M Isabelle; Andrea E DeBarber
Journal:  Clin Biochem       Date:  2010-12-23       Impact factor: 3.281

4.  Osmotic and nonosmotic regulation of arginine vasopressin during prolonged endurance exercise.

Authors:  Tamara Hew-Butler; Esme Jordaan; Kristin J Stuempfle; Dale B Speedy; Arthur J Siegel; Timothy D Noakes; Steven J Soldin; Joseph G Verbalis
Journal:  J Clin Endocrinol Metab       Date:  2008-03-18       Impact factor: 5.958

5.  Rapid measurement of estrogens and their metabolites in human serum by liquid chromatography-tandem mass spectrometry without derivatization.

Authors:  Tiedong Guo; Jianghong Gu; Offie P Soldin; Ravinder J Singh; Steven J Soldin
Journal:  Clin Biochem       Date:  2008-03-07       Impact factor: 3.281

6.  Principles and applications of liquid chromatography-mass spectrometry in clinical biochemistry.

Authors:  James J Pitt
Journal:  Clin Biochem Rev       Date:  2009-02

7.  Acute changes in arginine vasopressin, sweat, urine and serum sodium concentrations in exercising humans: does a coordinated homeostatic relationship exist?

Authors:  T Hew-Butler; T D Noakes; S J Soldin; J G Verbalis
Journal:  Br J Sports Med       Date:  2008-09-18       Impact factor: 13.800

8.  LC-MS/MS in the Clinical Laboratory - Where to From Here?

Authors:  Stefan Kg Grebe; Ravinder J Singh
Journal:  Clin Biochem Rev       Date:  2011-02

9.  LC-MS/MS detection of increased androstenedione levels in patients receiving danazol therapy.

Authors:  Verena Gounden; Diala El-Maouche; Brian R Stolze; Ranganath Muniyappa; Steven J Soldin
Journal:  Ther Drug Monit       Date:  2014-12       Impact factor: 3.681

10.  Revisiting hyper- and hypo-androgenism by tandem mass spectrometry.

Authors:  Flaminia Fanelli; Alessandra Gambineri; Marco Mezzullo; Valentina Vicennati; Carla Pelusi; Renato Pasquali; Uberto Pagotto
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.