Daytime ambulatory systolic blood pressure is more effective at predicting mortality than clinic blood pressure.

Martin G Dawes1, Andrew J Coats, Edmund Juszczak.   

Abstract

OBJECTIVES: To assess the prognostic value of daytime ambulatory blood pressure compared with routine clinic blood pressure in determining mortality.
METHODS: Prospective multicentre study in 48 general practices in Oxfordshire, a hypertension clinic in Oxford and a hypertension clinic in London.
RESULTS: A cohort of 10 129 patients from Oxford and London was followed up for a median of 8.2 years. Nine hundred and one deaths were recorded (8.9%) corresponding to a mortality rate per 1000 years of follow-up of 10.8 (99% confidence interval 9.9-11.8). Comparing the highest quartile for systolic ambulatory blood pressure with the lowest (>or=160 vs. <135 mmHg) gives an estimated age sex-adjusted hazard ratio for mortality of 1.51 (95% confidence interval 1.25-1.83, P<0.001). The corresponding comparison for clinic systolic blood pressure (>or=174 vs. <148 mmHg) results in a hazard ratio of 1.02 (95% confidence interval 0.84-1.24, P=0.9). Comparing ambulatory versus clinic systolic blood pressure (10 mmHg groupings) using nested statistical modelling, removal of the ambulatory blood pressure term from the baseline Cox model (nine 10 mmHg categories) resulted in a highly significant likelihood ratio test statistic of 52.5 (df=8, P<0.0001). The corresponding result for removal of the clinic blood pressure term was 18.1 (df=8, P=0.02), thus reinforcing the finding that ambulatory blood pressure monitoring has greater prognostic significance. Ambulatory blood pressure was also a better predictor of all-cause mortality both in patients taking medication and those not taking medication at the time of monitoring.
CONCLUSION: Daytime ambulatory blood pressure monitoring is a much better prognostic indicator of all-cause mortality than clinic blood pressure.

Entities:  

Mesh:

Year:  2006        PMID: 16702819     DOI: 10.1097/01.mbp.0000209086.32493.bd

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  9 in total

1.  Ambulatory Blood Pressure Variability Increases Over a 10-Year Follow-Up in Community-Dwelling Older People.

Authors:  Claire McDonald; Mark S Pearce; Joanna Wincenciak; Simon R J Kerr; Julia L Newton
Journal:  Am J Hypertens       Date:  2015-08-26       Impact factor: 2.689

2.  Understanding the connection between spiritual well-being and physical health: an examination of ambulatory blood pressure, inflammation, blood lipids and fasting glucose.

Authors:  Julianne Holt-Lunstad; Patrick R Steffen; Jonathan Sandberg; Bryan Jensen
Journal:  J Behav Med       Date:  2011-04-13

Review 3.  Clinical Implications of Different Blood Pressure Measurement Techniques.

Authors:  Paul Drawz
Journal:  Curr Hypertens Rep       Date:  2017-07       Impact factor: 5.369

Review 4.  Social Ambivalence and Disease (SAD): A Theoretical Model Aimed at Understanding the Health Implications of Ambivalent Relationships.

Authors:  Julianne Holt-Lunstad; Bert N Uchino
Journal:  Perspect Psychol Sci       Date:  2019-09-18

5.  Reproducibility of blood pressure dipping: relation to day-to-day variability in sleep quality.

Authors:  Alan L Hinderliter; Faye S Routledge; James A Blumenthal; Gary Koch; Michael A Hussey; William K Wohlgemuth; Andrew Sherwood
Journal:  J Am Soc Hypertens       Date:  2013-07-12

6.  Comparing the effects of white coat hypertension and sustained hypertension on mortality in a UK primary care setting.

Authors:  Martin G Dawes; Gillian Bartlett; Andrew J Coats; Edmund Juszczak
Journal:  Ann Fam Med       Date:  2008 Sep-Oct       Impact factor: 5.166

7.  Discordance between ambulatory versus clinic blood pressure according to global cardiovascular risk group.

Authors:  Jinho Shin; Sung Ha Park; Ju Han Kim; Sang Hyun Ihm; Kwang-il Kim; Woo Shik Kim; Wook Bum Pyun; Yu-Mi Kim; Sung-il Choi; Soon Kil Kim
Journal:  Korean J Intern Med       Date:  2015-08-27       Impact factor: 2.884

8.  Prevalence of resistant hypertension and associated factors for blood pressure control status with optimal medical therapy using Korean ambulatory blood pressure monitoring registry data.

Authors:  Sung Il Choi; Soon Kil Kim; Sungha Park; Ju Han Kim; Sang Hyun Ihm; Gwang-Il Kim; Woo Shik Kim; Wook Bum Pyun; Yu-Mi Kim; Jinho Shin
Journal:  Clin Hypertens       Date:  2016-01-27

9.  A Short History of Automated Office Blood Pressure - 15 Years to SPRINT.

Authors:  Martin G Myers
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-04-01       Impact factor: 3.738

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.