Literature DB >> 16701867

Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium.

G Mabilleau1, S Bourdon, M L Joly-Guillou, R Filmon, M F Baslé, D Chappard.   

Abstract

Titanium is widely used in dental implantology and orthopaedics due to its excellent corrosion resistance and mechanical properties. However, it has been reported that Ti is sensitive to F(-), H(2)O(2) and lactic acid. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) were used to investigate the corrosion resistance of CP-Ti disks after 9 days immersion in different test solutions, based on artificial saliva containing F(-) (0.5% and 2.5%), H(2)O(2) (0.1% and 10%) and/or lactic acid. Because activated macrophages and bacteria can also release locally some of these oxidative compounds, we investigated the role of these cells when plated onto titanium disks. The surface roughness (R(a)) was highly increased when titanium disks were immersed in artificial saliva containing F(-), H(2)O(2) and lactic acid. After 21 days of cell culture, R(a) was significantly increased on disks incubated with activated-J774.2 cells or Streptococcus mitis. AFM appeared to be more sensitive than SEM in evaluating the corrosion of the titanium. Chemical species, either environmental or those released by macrophages and bacteria, can provoke a marked attack of the titanium surface.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16701867     DOI: 10.1016/j.actbio.2005.09.004

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  25 in total

1.  Corrosion behaviour of titanium after short-term exposure to an acidic environment containing fluoride ions.

Authors:  Ludek Joska; Jaroslav Fojt
Journal:  J Mater Sci Mater Med       Date:  2010-02       Impact factor: 3.896

2.  Stability of plasma electrolytic oxidation coating on titanium in artificial saliva.

Authors:  E Matykina; R Arrabal; M Mohedano; A Pardo; M C Merino; E Rivero
Journal:  J Mater Sci Mater Med       Date:  2012-10-17       Impact factor: 3.896

3.  Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.

Authors:  F Rosalbino; S Delsante; G Borzone; G Scavino
Journal:  J Mater Sci Mater Med       Date:  2012-03-02       Impact factor: 3.896

4.  Long-term durability of orthodontic mini-implants.

Authors:  Mona Aly Abbassy; Ahmed Samir Bakry; Khalid Hashim Zawawi; Ali Habib Hassan
Journal:  Odontology       Date:  2017-08-24       Impact factor: 2.634

5.  Electrochemical corrosion behaviour of dental/implant alloys in saline medium.

Authors:  Mohit Sharma; A V Ramesh Kumar; Nirbhay Singh
Journal:  J Mater Sci Mater Med       Date:  2008-01-16       Impact factor: 3.896

6.  Corrosion Performance of Fe-Cr-Ni Alloys in Artificial Saliva and Mouthwash Solution.

Authors:  J Porcayo-Calderon; M Casales-Diaz; V M Salinas-Bravo; L Martinez-Gomez
Journal:  Bioinorg Chem Appl       Date:  2015-05-06       Impact factor: 7.778

7.  Tantalum Nitride-Decorated Titanium with Enhanced Resistance to Microbiologically Induced Corrosion and Mechanical Property for Dental Application.

Authors:  Yifei Zhang; Yunfei Zheng; Yongliang Li; Lixin Wang; Yanjie Bai; Qiang Zhao; Xiaoling Xiong; Yan Cheng; Zhihui Tang; Yi Deng; Shicheng Wei
Journal:  PLoS One       Date:  2015-06-24       Impact factor: 3.240

8.  Lipopolysaccharide inhibits or accelerates biomedical titanium corrosion depending on environmental acidity.

Authors:  Fei Yu; Owen Addison; Stephen J Baker; Alison J Davenport
Journal:  Int J Oral Sci       Date:  2015-09-14       Impact factor: 6.344

9.  Different corrosive effects on hydroxyapatite nanocrystals and amine fluoride-based mouthwashes on dental titanium brackets: a comparative in vitro study.

Authors:  Marco Lelli; Olivia Marchisio; Ismaela Foltran; Annamaria Genovesi; Giulia Montebugnoli; Massimo Marcaccio; Ugo Covani; Norberto Roveri
Journal:  Int J Nanomedicine       Date:  2013-01-17

10.  Diabetes as a Risk Factor for Orthopedic Implant Surface Performance: A Retrieval and In Vitro Study.

Authors:  Alexandra Arteaga; Jiayi Qu; Sara Haynes; Brian G Webb; Javier LaFontaine; Danieli C Rodrigues
Journal:  J Bio Tribocorros       Date:  2021-02-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.