BACKGROUND AND
PURPOSE: The underdose near air cavities in the head and neck region at photon energies of 4 MV and 6 MV was studied in search for clinical advantages of the 4 MV over 6 MV treatments.
MATERIALS AND METHODS: The on-axis and off-axis dose distributions were measured with a parallel-plate ionization chamber and films in polystyrene phantoms containing an air cavity of appropriate size based on the results of computed tomography scans.
RESULTS: Although most results are similar for both energies, the 4 MV photon beams give a somewhat smaller underdose effect and a faster re-build up than the 6 MV. For both energies a significant underdose effect was observed at the edge of the field in the larynx phantom. This proved to be true for small and large fields, for smaller and larger cavities, for one-beam as well as parallel-opposed beams.
CONCLUSION: For most clinically relevant situations there is no remarkable benefit in the use of either of the two energies.

Entities:  

Mesh:

Year:  2006        PMID: 16698100     DOI: 10.1016/j.radonc.2006.04.002

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Investigating the Effect of Air Cavities of Sinuses on the Radiotherapy Dose Distribution Using Monte Carlo Method.

Authors:  F Seif; M R Bayatiani; S Hamidi; M Kargaran
Journal:  J Biomed Phys Eng       Date:  2019-02-01

2.  Measurement of skin and target dose in post-mastectomy radiotherapy using 4 and 6 MV photon beams.

Authors:  Melanie Fischbach; Roger A Hälg; Matthias Hartmann; Jürgen Besserer; Günther Gruber; Uwe Schneider
Journal:  Radiat Oncol       Date:  2013-11-16       Impact factor: 3.481

3.  Optimization of photon beam energy in aperture-based inverse planning.

Authors:  Jason St-Hilaire; Caroline Sévigny; Frédéric Beaulieu; Luc Gingras; Daniel Tremblay; Luc Beaulieu
Journal:  J Appl Clin Med Phys       Date:  2009-09-03       Impact factor: 2.102

4.  Dosimetric evaluation of the Acuros XB algorithm for a 4 MV photon beam in head and neck intensity-modulated radiation therapy.

Authors:  Kimiko Hirata; Mitsuhiro Nakamura; Michio Yoshimura; Nobutaka Mukumoto; Manabu Nakata; Hitoshi Ito; Haruo Inokuchi; Yukinori Matsuo; Takashi Mizowaki; Masahiro Hiraoka
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.