Literature DB >> 16696463

Characterization of the phantom material virtual water in high-energy photon and electron beams.

M R McEwen1, D Niven.   

Abstract

The material Virtual Water has been characterized in photon and electron beams. Range-scaling factors and fluence correction factors were obtained, the latter with an uncertainty of around 0.2%. This level of uncertainty means that it may be possible to perform dosimetry in a solid phantom with an accuracy approaching that of measurements in water. Two formulations of Virtual Water were investigated with nominally the same elemental composition but differing densities. For photon beams neither formulation showed exact water equivalence-the water/Virtual Water dose ratio varied with the depth of measurement with a difference of over 1% at 10 cm depth. However, by using a density (range) scaling factor very good agreement (<0.2%) between water and Virtual Water at all depths was obtained. In the case of electron beams a range-scaling factor was also required to match the shapes of the depth dose curves in water and Virtual Water. However, there remained a difference in the measured fluence in the two phantoms after this scaling factor had been applied. For measurements around the peak of the depth-dose curve and the reference depth this difference showed some small energy dependence but was in the range 0.1%-0.4%. Perturbation measurements have indicated that small slabs of material upstream of a detector have a small (<0.1% effect) on the chamber reading but material behind the detector can have a larger effect. This has consequences for the design of experiments and in the comparison of measurements and Monte Carlo-derived values.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16696463     DOI: 10.1118/1.2174186

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

Authors:  Malcolm McEwen; Larry DeWerd; Geoffrey Ibbott; David Followill; David W O Rogers; Stephen Seltzer; Jan Seuntjens
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

2.  Dosimetric impact of density variations in Solid Water 457 water-equivalent slabs.

Authors:  Dale W Litzenberg; Hanan Amro; Joann I Prisciandaro; Eduardo Acosta; Ian Gallagher; Don A Roberts
Journal:  J Appl Clin Med Phys       Date:  2011-04-22       Impact factor: 2.102

3.  Evaluation of backscatter dose from internal lead shielding in clinical electron beams using EGSnrc Monte Carlo simulations.

Authors:  Rowen J De Vries; Steven Marsh
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

4.  Solid water phantom heat conduction: Heating and cooling rates.

Authors:  Martin J Butson; Tsang Cheung; Peter K N Yu
Journal:  J Med Phys       Date:  2008-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.