Measurement of blood pressure in the obese.

R J Prineas1.   

Abstract

There is a need for caution in measuring blood pressure in the obese. Problems related to adequate cuff-bladder size and shape are apparent from a review of the literature. Imperfections in experiments comparing intra-arterial/indirect blood pressure measurements remain. Cuff characteristics, as well as cuff-bladder width and length, can bias measurement of blood pressure in the obese. Authoritative committee recommendations and the differing needs of blood pressure measurement in obese adults and children still need to be rationalized. Manufacturing faults of cuff bladder and cuff availability continue to be a problem for blood pressure measurement in the obese. Measurement of blood pressure in large obese and large muscular arms may require different adjustments for cuff width and arm circumference. Nomograms for adjusting blood pressure recording in the obese are inadequate. The most important adjustment for measuring blood pressure in the obese derives from choosing the correct cuff width-arm circumference (CW/AC) ratio. Such action reduces the intersubject variability of blood pressure measurement in clinical and epidemiologic studies. Past studies probably overestimated blood pressure level in the obese and so underestimated the risk of elevated blood pressure in the obese.

Entities:  

Mesh:

Year:  1991        PMID: 1669514     DOI: 10.1016/1047-2797(91)90043-c

Source DB:  PubMed          Journal:  Ann Epidemiol        ISSN: 1047-2797            Impact factor:   3.797


  5 in total

1.  Validating prediction equations for mid-arm circumference measurements in adults: National Health and Nutrition Examination Survey, 2001-2012.

Authors:  Tatiana Nwankwo; Yechiam Ostchega; Guangyu Zhang; Jeffery P Hughes
Journal:  Blood Press Monit       Date:  2015-06       Impact factor: 1.444

2.  Patterns of intra-arterial blood pressure monitoring for patients undergoing total shoulder arthroplasty under general anesthesia: a retrospective analysis of 23,073 patients.

Authors:  Rodney A Gabriel; Anair Beverly; Richard P Dutton; Richard D Urman
Journal:  J Clin Monit Comput       Date:  2016-10-13       Impact factor: 2.502

3.  Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016.

Authors:  Yechiam Ostchega; Jeffery P Hughes; Tatiana Nwankwo; Guangyu Zhang
Journal:  Blood Press Monit       Date:  2018-12       Impact factor: 1.444

4.  The correlation between body mass index, limb circumferences and blood pressure cuff fit in bariatric surgical patients.

Authors:  R Schumann; O Alyamani; A Viswanath; I Bonney
Journal:  Saudi J Anaesth       Date:  2016 Apr-Jun

5.  Measurement of the ankle brachial index with a non-mercury sphygmomanometer in diabetic patients: a concordance study.

Authors:  Magdalena Bundó; Magali Urrea; Laura Muñoz-Ortíz; Carmen Pérez; Judit Llussà; Rosa Forés; María Teresa Alzamora; Pere Torán
Journal:  BMC Cardiovasc Disord       Date:  2013-03-08       Impact factor: 2.298

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.