Literature DB >> 16688069

The safety of fluoroscopically-assisted thoracic pedicle screw instrumentation for spine trauma.

Richard Bransford1, Carlo Bellabarba, Jason H Thompson, M Bradford Henley, Sohail K Mirza, Jens R Chapman.   

Abstract

BACKGROUND: Pedicle screw fixation is considered biomechanically superior to other stabilization constructs. However, the potential for severe complications have discouraged its use in the thoracic spine. Our goal is to determine the incidence of major perioperative complications following the placement of thoracic pedicle screws using anatomic landmarks and intraoperative fluoroscopy in patients with spine fractures.
METHODS: Retrospective review of 245 consecutive patients with spine fractures requiring pedicle screw fixation between T1 and T10 at a regional Level I trauma center between 1995 and 2001. Database and medical record review were used to identify the incidence of major perioperative complications. A major complication was defined as a potentially life-threatening vascular injury, neurologic deterioration, pneumothorax or hemothorax, and tracheoesophageal injury. Patients were monitored for these complications from the time of surgery until discharge.
RESULTS: In all, 1,533 pedicle screws were placed between T1 and T10 in 245 patients. No patient sustained a major complication related to screw placement. Three patients (1.2%) required a secondary procedure for prophylactic revision of four (0.26%) malpositioned screws.
CONCLUSIONS: This study supports the safety of pedicle screws in the thoracic spine using preoperative imaging evaluation, standard posterior element landmarks and intraoperative fluoroscopy.

Entities:  

Mesh:

Year:  2006        PMID: 16688069     DOI: 10.1097/01.ta.0000215949.95089.18

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  10 in total

1.  Thoracic spine fractures: injury profile and outcomes of a surgically treated cohort.

Authors:  Bartolomé Marré; Vicente Ballesteros; Celmira Martínez; Juan J Zamorano; Francisco Ilabaca; Milan Munjin; Ratko Yurac; Alejandro Urzúa; Miguel Lecaros; José Fleiderman
Journal:  Eur Spine J       Date:  2011-01-28       Impact factor: 3.134

2.  Safety of thoracic pedicle screw application using the funnel technique in Asians: a cadaveric evaluation.

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

3.  Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.

Authors:  Markus Beck; Thomas Mittlmeier; Philip Gierer; Christoph Harms; Georg Gradl
Journal:  Eur Spine J       Date:  2009-06-10       Impact factor: 3.134

4.  Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws.

Authors:  Chang Hyun Oh; Seung Hwan Yoon; Yongjung J Kim; Dongkeun Hyun; Hyeong-Chun Park
Journal:  Korean J Spine       Date:  2013-03-31

5.  [Operative treatment of traumatic fractures of the thorax and lumbar spine. Part II: surgical treatment and radiological findings].

Authors:  M Reinhold; C Knop; R Beisse; L Audigé; F Kandziora; A Pizanis; R Pranzl; E Gercek; M Schultheiss; A Weckbach; V Bühren; M Blauth
Journal:  Unfallchirurg       Date:  2009-02       Impact factor: 1.000

6.  Free-hand thoracic pedicle screws placed by neurosurgery residents: a CT analysis.

Authors:  Vincent Y Wang; Cynthia T Chin; Daniel C Lu; Justin S Smith; Dean Chou
Journal:  Eur Spine J       Date:  2010-02-05       Impact factor: 3.134

7.  Three-dimensional Fluoroscopy-based Navigation for the Pedicle Screw Placement in Patients with Primary Invasive Spinal Tumors.

Authors:  Bo Jin; Yi-Bing Su; Ji-Zong Zhao
Journal:  Chin Med J (Engl)       Date:  2016-11-05       Impact factor: 2.628

8.  Radiation Exposure in Posterior Lumbar Fusion: A Comparison of CT Image-Guided Navigation, Robotic Assistance, and Intraoperative Fluoroscopy.

Authors:  Erik Wang; Jordan Manning; Christopher G Varlotta; Dainn Woo; Ethan Ayres; Edem Abotsi; Dennis Vasquez-Montes; Themistocles S Protopsaltis; Jeffrey A Goldstein; Anthony K Frempong-Boadu; Peter G Passias; Aaron J Buckland
Journal:  Global Spine J       Date:  2020-02-27

9.  The Indian Basket Trick: a case of delayed paraplegia with complete recovery, caused by misplaced thoracic pedicle screw.

Authors:  Antonin Leroy; Reda Kabbaj; Arnaud Dubory; Manon Bachy; Anne-Isabelle Vermersch; Raphaël Vialle
Journal:  Springerplus       Date:  2016-06-30

Review 10.  Biomechanics and clinical outcome after posterior stabilization of mid-thoracic vertebral body fractures: a systematic literature review.

Authors:  Ulrich J Spiegl; Georg Osterhoff; Philipp Bula; Frank Hartmann; Max J Scheyerer; Klaus J Schnake; Bernhard W Ullrich
Journal:  Eur J Trauma Emerg Surg       Date:  2020-12-02       Impact factor: 3.693

  10 in total