Literature DB >> 16683937

Cleaning products and air fresheners: emissions and resulting concentrations of glycol ethers and terpenoids.

B C Singer1, H Destaillats, A T Hodgson, W W Nazaroff.   

Abstract

UNLABELLED: Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m3 room ventilated at approximately 0.5/h. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 microg/m3 for individual terpenoids, including alpha-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and alpha-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or d-limonene were 300-6000 microg/m3 after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, and approximately 25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were approximately 35-70% with towels retained, and 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and beta-citronellol) were emitted at 35-180 mg/day over 3 days while air concentrations averaged 30-160 microg/m3. PRACTICAL IMPLICATIONS: While effective cleaning can improve the healthfulness of indoor environments, this work shows that use of some consumer cleaning agents can yield high levels of volatile organic compounds, including glycol ethers--which are regulated toxic air contaminants--and terpenes that can react with ozone to form a variety of secondary pollutants including formaldehyde and ultrafine particles. Persons involved in cleaning, especially those who clean occupationally or often, might encounter excessive exposures to these pollutants owing to cleaning product emissions. Mitigation options include screening of product ingredients and increased ventilation during and after cleaning. Certain practices, such as the use of some products in dilute solution vs. full-strength and the prompt removal of cleaning supplies from occupied spaces, can reduce emissions and exposures to 2-butoxyethanol and other volatile constituents. Also, it may be prudent to limit use of products containing ozone-reactive constituents when indoor ozone concentrations are elevated either because of high ambient ozone levels or because of the indoor use of ozone-generating equipment.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16683937     DOI: 10.1111/j.1600-0668.2005.00414.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  37 in total

1.  Indoor air quality in elementary schools of Lisbon in spring.

Authors:  P N Pegas; C A Alves; M G Evtyugina; T Nunes; M Cerqueira; M Franchi; C A Pio; S M Almeida; M C Freitas
Journal:  Environ Geochem Health       Date:  2010-11-02       Impact factor: 4.609

2.  Formaldehyde in the indoor environment.

Authors:  Tunga Salthammer; Sibel Mentese; Rainer Marutzky
Journal:  Chem Rev       Date:  2010-04-14       Impact factor: 60.622

Review 3.  The role of the healthcare environment in the spread of multidrug-resistant organisms: update on current best practices for containment.

Authors:  Roy F Chemaly; Sarah Simmons; Charles Dale; Shashank S Ghantoji; Maria Rodriguez; Julie Gubb; Julie Stachowiak; Mark Stibich
Journal:  Ther Adv Infect Dis       Date:  2014-06

4.  Indoor-biofilter growth and exposure to airborne chemicals drive similar changes in plant root bacterial communities.

Authors:  Jacob A Russell; Yi Hu; Linh Chau; Margarita Pauliushchyk; Ioannis Anastopoulos; Shivanthi Anandan; Michael S Waring
Journal:  Appl Environ Microbiol       Date:  2014-05-30       Impact factor: 4.792

5.  Personal exposure to mixtures of volatile organic compounds: modeling and further analysis of the RIOPA data.

Authors:  Stuart Batterman; Feng-Chiao Su; Shi Li; Bhramar Mukherjee; Chunrong Jia
Journal:  Res Rep Health Eff Inst       Date:  2014-06

6.  Toxicological analysis of limonene reaction products using an in vitro exposure system.

Authors:  Stacey E Anderson; Shahana S Khurshid; B Jean Meade; Ewa Lukomska; J R Wells
Journal:  Toxicol In Vitro       Date:  2012-12-07       Impact factor: 3.500

Review 7.  Update on asthma and cleaners.

Authors:  Jan-Paul Zock; David Vizcaya; Nicole Le Moual
Journal:  Curr Opin Allergy Clin Immunol       Date:  2010-04

8.  Maternal occupation and term low birth weight in a predominantly latina population in los angeles, california.

Authors:  Ondine S von Ehrenstein; Michelle Wilhelm; Beate Ritz
Journal:  J Occup Environ Med       Date:  2013-09       Impact factor: 2.162

9.  Volatile pollutants emitted from selected liquid household products.

Authors:  Ki-Dong Kwon; Wan-Kuen Jo; Ho-Jin Lim; Woo-Sik Jeong
Journal:  Environ Sci Pollut Res Int       Date:  2008-08-08       Impact factor: 4.223

10.  Characterization of occupational exposures to cleaning products used for common cleaning tasks--a pilot study of hospital cleaners.

Authors:  Anila Bello; Margaret M Quinn; Melissa J Perry; Donald K Milton
Journal:  Environ Health       Date:  2009-03-27       Impact factor: 5.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.