Literature DB >> 16678026

Initial experience with non-thoracic, extraperitoneal, off-pump insertion of the Jarvik 2000 Heart in patients with previous median sternotomy.

O H Frazier1, Igor D Gregoric, William E Cohn.   

Abstract

BACKGROUND: Successful implantation of left ventricular assist devices (LVADs) in patients with previous median sternotomy remains challenging.
METHODS: Seven patients underwent implantation of a Jarvik 2000 Heart by an extrathoracic, extraperitoneal, sub-costal surgical approach, which allows easy exposure of the diaphragmatic surface of the heart and the supraceliac aorta. All patients were at very high risk and were receiving high doses of inotropic agents to maintain their cardiac function. All had undergone prior median sternotomy. We compared data for blood loss and intensive care unit (ICU) stay with those of 15 patients in whom the HeartMate I vented electric LVAD was placed through a re-do sternotomy incision.
RESULTS: All 7 patients survived the surgical procedure for implantation of the Jarvik 2000. All 7 patients were rapidly rehabilitated and had a short stay in the ICU (mean 3.3 days, range 1 to 8 days), as compared with the re-do HeartMate patients (mean 10.3 days, range 3 to 33 days) (p = 0.005). The average 12-hour blood loss was 635 ml in the Jarvik patients compared with 2,405 ml in the re-do HeartMate patients (p = 0.028). The cardiac index improved significantly in all Jarvik patients.
CONCLUSIONS: The extrathoracic, extraperitoneal, sub-costal surgical approach is less invasive than a median sternotomy and allows the Jarvik 2000 to be implanted quickly and without cardiopulmonary bypass (CPB). By avoiding CPB and an extensive mediastinal dissection, bleeding is decreased in these hypocoagulable patients with compromised end-organ function. The decreased operative morbidity and mortality associated with this technique may allow consideration of the Jarvik 2000 Heart for safe and effective implantation in home-bound New York Heart Association (NYHA) Class III and IV patients.

Entities:  

Mesh:

Year:  2006        PMID: 16678026     DOI: 10.1016/j.healun.2005.12.003

Source DB:  PubMed          Journal:  J Heart Lung Transplant        ISSN: 1053-2498            Impact factor:   10.247


  6 in total

1.  New tools and techniques to facilitate off-pump left ventricular assist device implantation.

Authors:  William E Cohn
Journal:  Tex Heart Inst J       Date:  2010

2.  In vivo evaluation of the HeartWare centrifugal ventricular assist device.

Authors:  Egemen Tuzun; Katy Roberts; William E Cohn; Murat Sargin; Courtney J Gemmato; Branislav Radovancevic; O H Frazier
Journal:  Tex Heart Inst J       Date:  2007

Review 3.  Left ventricular assist devices as a bridge to cardiac transplantation.

Authors:  Christopher T Holley; Laura Harvey; Ranjit John
Journal:  J Thorac Dis       Date:  2014-08       Impact factor: 2.895

Review 4.  Miniaturization of mechanical circulatory support systems.

Authors:  Guruprasad A Giridharan; Thomas J Lee; Mickey Ising; Michael A Sobieski; Steven C Koenig; Laman A Gray; Mark S Slaughter
Journal:  Artif Organs       Date:  2012-08       Impact factor: 3.094

5.  The TandemHeart as a bridge to a long-term axial-flow left ventricular assist device (bridge to bridge).

Authors:  Igor D Gregoric; Leon P Jacob; Saverio La Francesca; Brian A Bruckner; William E Cohn; Pranav Loyalka; Biswajit Kar; O H Frazier
Journal:  Tex Heart Inst J       Date:  2008

6.  2019 EACTS Expert Consensus on long-term mechanical circulatory support.

Authors:  Evgenij V Potapov; Christiaan Antonides; Maria G Crespo-Leiro; Alain Combes; Gloria Färber; Margaret M Hannan; Marian Kukucka; Nicolaas de Jonge; Antonio Loforte; Lars H Lund; Paul Mohacsi; Michiel Morshuis; Ivan Netuka; Mustafa Özbaran; Federico Pappalardo; Anna Mara Scandroglio; Martin Schweiger; Steven Tsui; Daniel Zimpfer; Finn Gustafsson
Journal:  Eur J Cardiothorac Surg       Date:  2019-08-01       Impact factor: 4.191

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.