Literature DB >> 16674624

A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study.

A Evans1, S Morris, J Petterson, J E Hall.   

Abstract

Management of the difficult airway is one of the major challenges that anaesthetists face. The flexible fibreoptic scope is widely available but its use requires a level of skill, training and continued practice that is not universally found in all anaesthetists, particularly trainees. The Seeing Optical Stylet is a new, semirigid fibreoptic stylet 'scope. We compared the Seeing Optical Stylet with a gum elastic bougie in a simulated Cormack and Lehane Grade 3 laryngoscopy in a manikin. Forty-four anaesthetists were timed while intubating the manikin's trachea with both devices. The mean (SD) time taken with the Seeing Optical Stylet was 20.8 (9.3) s and with the bougie 30 (19.8) s (p = 0.001). Oesophageal intubation occurred six times with the bougie but did not occur with the Seeing Optical Stylet (p = 0.011). We conclude that the Seeing Optical Stylet may be superior to the bougie in difficult tracheal intubation. We feel that the results of this manikin trial are sufficiently encouraging to proceed to a clinical trial in patients.

Entities:  

Mesh:

Year:  2006        PMID: 16674624     DOI: 10.1111/j.1365-2044.2006.04539.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  5 in total

1.  Performance of emergency physicians utilizing a video-assisted semi-rigid fiberoptic stylet for intubation of a difficult airway in a high-fidelity simulated patient: a pilot study.

Authors:  Derek R Cooney; Norma L Cooney; Harry Wallus; Susan Wojcik
Journal:  Int J Emerg Med       Date:  2012-05-29

2.  Comparison of the new flexible tip bougie catheter and standard bougie stylet for tracheal intubation by anesthesiologists in different difficult airway scenarios: a randomized crossover trial.

Authors:  Kurt Ruetzler; Jacek Smereka; Cristian Abelairas-Gomez; Michael Frass; Marek Dabrowski; Szymon Bialka; Hanna Misiolek; Tadeusz Plusa; Oliver Robak; Olga Aniolek; Jerzy Robert Ladny; Damian Gorczyca; Sanchit Ahuja; Lukasz Szarpak
Journal:  BMC Anesthesiol       Date:  2020-04-20       Impact factor: 2.217

3.  Utility of a gum-elastic bougie for difficult airway management in infants: a simulation-based crossover analysis.

Authors:  Nobuyasu Komasawa; Akira Hyoda; Sayuri Matsunami; Nozomi Majima; Toshiaki Minami
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

4.  Endotracheal intubation in patients with difficult airway: using laryngeal mask airway with bougie versus video laryngoscopy.

Authors:  Hesameddin Modir; Esmail Moshiri; Bita Malekianzadeh; Gholamreza Noori; Abolfazl Mohammadbeigi
Journal:  Med Gas Res       Date:  2017-10-17

5.  Comparison of three tracheal intubation techniques in thyroid tumor patients with a difficult airway: a randomized controlled trial.

Authors:  Ling Liu; Hui Yue; Jincheng Li
Journal:  Med Princ Pract       Date:  2014-08-23       Impact factor: 1.927

  5 in total