Tribological principles in metal-on-metal hip joint design.

D Dowson1.   

Abstract

An analysis of some 100 published and communicated findings on running-in volumetric wear and steady state wear rates from simulator tests carried out in eight laboratories in three countries has been undertaken. Powerful indications have emerged of the dominant role of mixed lubrication in current metal-on-metal hip replacements, with elastohydrodynamic film thickness controlling wear. The background to the calculation of film thickness in the elastic-isoviscous mode of lubrication has been outlined and graphs of representative film thickness and lambda ratio have been presented. For minimum wear and wear rate the diameter of the femoral component should be as large as possible, while the clearance should be as small as is practicable. The findings are valid for both monolithic and surface replacement implants. A tentative proposal is made for the prediction of lifetime wear in metal-on-metal total hip replacements.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16669384     DOI: 10.1243/095441105X63255

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  7 in total

1.  Reduced articular surface of one-piece cups: a cause of runaway wear and early failure.

Authors:  William L Griffin; Christopher J Nanson; Bryan D Springer; Matthew A Davies; Thomas K Fehring
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

Review 2.  [Implant wear and aseptic loosening. An overview].

Authors:  C Kaddick; I Catelas; P H Pennekamp; M A Wimmer
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

3.  What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Authors:  Nick Bayley; Habeeb Khan; Paul Grosso; Thomas Hupel; David Stevens; Matthew Snider; Emil Schemitsch; Paul Kuzyk
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

Review 4.  [Biomechanical aspects of the implant fixation and kinematics of hip resurfacing systems].

Authors:  R Bader; D Klüss; L Gerdesmeyer; E Steinhauser
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

Review 5.  Mechanisms of Adverse Local Tissue Reactions to Hip Implants.

Authors:  Felipe Eltit; Qiong Wang; Rizhi Wang
Journal:  Front Bioeng Biotechnol       Date:  2019-07-30

6.  The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur.

Authors:  James K Lord; David J Langton; Antoni V F Nargol; R M Dominic Meek; Thomas J Joyce
Journal:  J Funct Biomater       Date:  2015-10-15

7.  Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients.

Authors:  Zhiwei Cui; Yi-Xing Tian; Wen Yue; Lei Yang; Qunyang Li
Journal:  Sci Rep       Date:  2016-06-27       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.