Literature DB >> 16652034

Evaluation of a low-cost method, the Guava EasyCD4 assay, to enumerate CD4-positive lymphocyte counts in HIV-infected patients in the United States and Uganda.

Lisa A Spacek1, Hasan M Shihab, Fred Lutwama, Jean Summerton, Harriet Mayanja, Moses Kamya, Allan Ronald, Joseph B Margolick, Tricia L Nilles, Thomas C Quinn.   

Abstract

OBJECTIVE: To evaluate the EasyCD4 assay, a less expensive method to enumerate CD4+ lymphocytes, in resource-limited settings.
DESIGN: Cross-sectional study conducted in the United States and Uganda.
METHODS: We compared CD4+ cell counts obtained on replicate samples from HIV-infected patients by the EasyCD4 assay, a microcapillary flow-based system, and by standard flow cytometry or FACSCount with linear regression and the Bland-Altman method.
RESULTS: Two hundred eighteen samples were analyzed (77 in the United States and 141 in Uganda). In the United States, mean +/- SD CD4 was 697 +/- 438 cells/microL by standard flow cytometry and 688 +/- 451 cells/microL by EasyCD4. In Uganda, the mean +/- SD CD4 was 335 +/- 331 cells/microL by FACSCount and 340 +/- 327 cells/microL by EasyCD4. The 2 methods were highly correlated (US cohort, r2 = 0.97, slope = 1.0, intercept = -18; Ugandan cohort, r2 = 0.92; slope = 0.95; intercept = 23). The mean differences in CD4 cell counts were 9.0 and -4.6 cells/microL for the US and Ugandan cohorts, respectively, and they were not significant in either cohort. In the Ugandan cohort, sensitivity and specificity of the EasyCD4 for CD4 below 200 cells/microL were 90% and 98%, respectively. Positive predictive value was 96%; negative predictive value was 93%.
CONCLUSIONS: Our results suggest that EasyCD4 may be used with high positive and negative predictive value in resource-limited settings.

Entities:  

Mesh:

Year:  2006        PMID: 16652034     DOI: 10.1097/01.qai.0000214807.98465.a2

Source DB:  PubMed          Journal:  J Acquir Immune Defic Syndr        ISSN: 1525-4135            Impact factor:   3.731


  14 in total

Review 1.  HIV/AIDS epidemiology, pathogenesis, prevention, and treatment.

Authors:  Viviana Simon; David D Ho; Quarraisha Abdool Karim
Journal:  Lancet       Date:  2006-08-05       Impact factor: 79.321

2.  Assessing agreement in the timing of treatment initiation determined by repeated measurements of novel versus gold standard technologies with application to the monitoring of CD4 counts in HIV-infected patients.

Authors:  Farzad Noubary; Michael D Hughes
Journal:  Stat Med       Date:  2010-08-15       Impact factor: 2.373

Review 3.  Nano/Microfluidics for diagnosis of infectious diseases in developing countries.

Authors:  Won Gu Lee; Yun-Gon Kim; Bong Geun Chung; Utkan Demirci; Ali Khademhosseini
Journal:  Adv Drug Deliv Rev       Date:  2009-11-30       Impact factor: 15.470

4.  Lensless imaging for point-of-care testing.

Authors:  SangJun Moon; Hasan Onur Keles; Yun-Gon Kim; Daniel Kuritzkes; Utkan Demirci
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

5.  Performance evaluation of the MBio Diagnostics point-of-care CD4 counter.

Authors:  Cathy Logan; Monique Givens; Jeffrey T Ives; Marie Delaney; Michael J Lochhead; Robert T Schooley; Constance A Benson
Journal:  J Immunol Methods       Date:  2012-10-11       Impact factor: 2.303

Review 6.  CD4 immunophenotyping in HIV infection.

Authors:  David Barnett; Brooke Walker; Alan Landay; Thomas N Denny
Journal:  Nat Rev Microbiol       Date:  2008-11       Impact factor: 60.633

7.  Integrating microfluidics and lensless imaging for point-of-care testing.

Authors:  Sangjun Moon; Hasan Onur Keles; Aydogan Ozcan; Ali Khademhosseini; Edward Haeggstrom; Daniel Kuritzkes; Utkan Demirci
Journal:  Biosens Bioelectron       Date:  2009-04-02       Impact factor: 10.618

8.  Rapid, effective and user-friendly immunophenotyping of canine lymphoma using a personal flow cytometer.

Authors:  Stratos Papakonstantinou; Inese Berzina; Amanda Lawlor; Emma J O'Neill; Peter J O'Brien
Journal:  Ir Vet J       Date:  2013-04-01       Impact factor: 2.146

9.  Validation of Microcapillary Flow Cytometry for Community-Based CD4+ T Lymphocyte Enumeration in Remote Burkina Faso.

Authors:  Cybèle A Renault; Arouna Traore; Rhoderick N Machekano; Dennis M Israelski
Journal:  Open AIDS J       Date:  2010-12-30

10.  Enumeration of CD4+ T-cells using a portable microchip count platform in Tanzanian HIV-infected patients.

Authors:  SangJun Moon; Umut Atakan Gurkan; Jeffrey Blander; Wafaie W Fawzi; Said Aboud; Ferdinand Mugusi; Daniel R Kuritzkes; Utkan Demirci
Journal:  PLoS One       Date:  2011-07-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.