Practical sources of error in measuring pulmonary artery occlusion pressure: a study in participants of a special intensivist training program of The Scandinavian Society of Anaesthesiology and Intensive Care Medicine (SSAI).

I Parviainen1, S M Jakob, M Suistomaa, J Takala.   

Abstract

BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP).
METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP.
RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses.
CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.

Entities:  

Mesh:

Year:  2006        PMID: 16643231     DOI: 10.1111/j.1399-6576.2006.001008.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  7 in total

1.  Health technology assessment in critical care.

Authors:  Damon C Scales; Andreas Laupacis
Journal:  Intensive Care Med       Date:  2007-10-20       Impact factor: 17.440

Review 2.  The pulmonary artery catheter.

Authors:  Jean-Louis Vincent
Journal:  J Clin Monit Comput       Date:  2012-08-12       Impact factor: 2.502

3.  Mechanical circulatory support device-heart hysteretic interaction can predict left ventricular end diastolic pressure.

Authors:  Brian Y Chang; Steven P Keller; Sonya S Bhavsar; Noam Josephy; Elazer R Edelman
Journal:  Sci Transl Med       Date:  2018-02-28       Impact factor: 17.956

4.  Dynamic Modulation of Device-Arterial Coupling to Determine Cardiac Output and Vascular Resistance.

Authors:  Steven P Keller; Brian Y Chang; Qing Tan; Zhengyang Zhang; Ahmad El Katerji; Elazer R Edelman
Journal:  Ann Biomed Eng       Date:  2020-04-13       Impact factor: 3.934

5.  The current state of fellowship training in pulmonary artery catheter placement and data interpretation: a national survey of pulmonary and critical care fellowship program directors.

Authors:  Melissa H Tukey; Renda Soylemez Wiener
Journal:  J Crit Care       Date:  2013-07-20       Impact factor: 3.425

6.  Pulmonary artery catheter use in adult patients undergoing cardiac surgery: a retrospective, cohort study.

Authors:  Andrew D Shaw; Michael G Mythen; Douglas Shook; David K Hayashida; Xuan Zhang; Jeffrey R Skaar; Sloka S Iyengar; Sibyl H Munson
Journal:  Perioper Med (Lond)       Date:  2018-10-25

Review 7.  The contemporary pulmonary artery catheter. Part 1: placement and waveform analysis.

Authors:  I T Bootsma; E C Boerma; F de Lange; T W L Scheeren
Journal:  J Clin Monit Comput       Date:  2021-02-10       Impact factor: 2.502

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.