Literature DB >> 16640641

Ex vivo accuracy of three electronic apex locators: Root ZX, Elements Diagnostic Unit and Apex Locator and ProPex.

G Plotino1, N M Grande, L Brigante, B Lesti, F Somma.   

Abstract

AIM: To compare ex vivo the accuracy of three electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator and ProPex.
METHODOLOGY: Electronic working length determination was carried out in 40 extracted teeth using an ex vivo model. After access preparation, a first operator determined the reference length (AL) for each tooth under a 30x stereomicroscope using the apical constriction as the apical landmark. All teeth were then measured with each EAL and the results obtained were compared with the corresponding AL. The AL was subtracted from the electronically determined distance. The measurements exceeding the AL were recorded as positive (long) and the measurements short of the AL were recorded as negative. Data were analyzed using the Friedman Test and Tukey multiple range test for nonparametric correlation amongst groups. Statistical significance was considered at P < 0.05.
RESULTS: Comparing the differences between measurements obtained with the three EALs and those obtained with the stereomicroscope, the percentage of measurements within +/-0.5 mm of the AL was 97.37% (84.22% within 0.5 mm short of AL) for the Root ZX, 94.28% (88.57% within 0.5 mm short of AL) for the Elements and 100% (35.9% within 0.5 mm short of AL) for the ProPex. The mean difference between the AL and the lengths measured by the Root ZX, the Elements and the ProPex were, respectively, -0.157 +/- 0.228, -0.103 +/- 0.359 and 0.307 +/- 0.271 mm.
CONCLUSIONS: The results of the present study confirm that the EALs determined the canal length within +/-0.5 mm from the apical constriction in the majority of cases. The majority of the ProPex readings were long.

Entities:  

Mesh:

Year:  2006        PMID: 16640641     DOI: 10.1111/j.1365-2591.2006.01095.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  27 in total

1.  Effect of pre-flaring and file size on the accuracy of two electronic apex locators.

Authors:  Manoel Brito-Júnior; Carla Cristina Camilo; Gil Moreira-Júnior; Jesus Djalma Pecora; Manoel Damião Sousa-Neto
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

2.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

3.  Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleymani; Jalil Modaresi; Mahsa Imanian; Malihe Lotfian
Journal:  J Dent (Tehran)       Date:  2015-04

4.  A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study.

Authors:  Irfana Khursheed; Ruchika Bansal; Tajinder Bansal; Harkanwal Preet Singh; Madhulika Yadav; K Jetender Reddy
Journal:  Dent Res J (Isfahan)       Date:  2014-01

5.  A comparative evaluation of electronic and radiographic determination of root canal length in primary teeth: An in vitro study.

Authors:  Iyer Satishkumar Krishnan; Sheela Sreedharan
Journal:  Contemp Clin Dent       Date:  2012-10

6.  The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study.

Authors:  Shiva Sadeghi; Masoomeh Abolghasemi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-05-15

7.  In Vitro Comparison of Raypex 6 and Endopilot Using a Novel, Computer-Aided Measurement System, for Determining the Working Length.

Authors:  David Christofzik; Falk Schwendicke; Christian Flörke; Alexander Härtl; Christof Dörfer; Birte Größner-Schreiber
Journal:  PLoS One       Date:  2015-08-03       Impact factor: 3.240

8.  An in vitro stereomicroscopic comparative evaluation of a combination of apex locator and endodontic motor with an integrated endodontic motor.

Authors:  Ch Swarupa; Girija S Sajjan; Yv Sashi Kanth
Journal:  J Conserv Dent       Date:  2013-09

9.  Evaluation of Two New Electronic Apex-Locator-Controlled Handpieces Using a NiTi Rotary File: An In Vitro Study.

Authors:  Kiumarz Nazarimoghadam; Hossein Labaf
Journal:  J Dent (Tehran)       Date:  2013-11-30

10.  Working Length Determination of Root Canal of Young Permanent Tooth: An In vitro Study.

Authors:  A Diwanji; As Rathore; R Arora; V Dhar; A Madhusudan; J Doshi
Journal:  Ann Med Health Sci Res       Date:  2014-07
View more