Literature DB >> 16634419

Patient state index.

David Drover1, H R Ortega.   

Abstract

The patient state index (PSI) is a clinically validated measure of the effect of anaesthesia and sedation. The PSI is calculated via a proprietary algorithm by a high-resolution 4-channel electroencephalograph (EEG) monitor after advanced artifact rejection. The PSI has been designed specifically for intra-operative and intensive care use to monitor patient sedation and drug effect. The algorithm relies on EEG power, frequency and phase information from anterior-posterior relationships of the brain as well as coherence between bilateral brain regions. The EEG monitor, initially called the PSA4000, is also the SEDLine monitor, the newest generation of the device. The SEDLine system provides the clinician the option of storing and downloading patient data for future use as well as monitoring bilateral brain function and symmetry with a density spectral array (DSA) display.

Entities:  

Mesh:

Year:  2006        PMID: 16634419     DOI: 10.1016/j.bpa.2005.07.008

Source DB:  PubMed          Journal:  Best Pract Res Clin Anaesthesiol        ISSN: 1521-6896


  37 in total

Review 1.  Clinical Electroencephalography for Anesthesiologists: Part I: Background and Basic Signatures.

Authors:  Patrick L Purdon; Aaron Sampson; Kara J Pavone; Emery N Brown
Journal:  Anesthesiology       Date:  2015-10       Impact factor: 7.892

2.  The Ageing Brain: Age-dependent changes in the electroencephalogram during propofol and sevoflurane general anaesthesia.

Authors:  P L Purdon; K J Pavone; O Akeju; A C Smith; A L Sampson; J Lee; D W Zhou; K Solt; E N Brown
Journal:  Br J Anaesth       Date:  2015-07       Impact factor: 9.166

3.  The Patient State Index is well balanced for propofol sedation.

Authors:  K H Lee; Y H Kim; Y J Sung; M K Oh
Journal:  Hippokratia       Date:  2015 Jul-Sep       Impact factor: 0.471

4.  The Feasibility and Utility of Continuous Sleep Monitoring in Critically Ill Patients Using a Portable Electroencephalography Monitor.

Authors:  Susana Vacas; Erin McInrue; Michael A Gropper; Mervyn Maze; Rochelle Zak; Eunjung Lim; Jacqueline M Leung
Journal:  Anesth Analg       Date:  2016-07       Impact factor: 5.108

5.  Sedation in adults receiving mechanical ventilation: physiological and comfort outcomes.

Authors:  Mary Jo Grap; Cindy L Munro; Paul A Wetzel; Al M Best; Jessica M Ketchum; V Anne Hamilton; Nyimas Y Arief; Rita Pickler; Curtis N Sessler
Journal:  Am J Crit Care       Date:  2012-05       Impact factor: 2.228

Review 6.  Noninvasive Monitoring and Potential for Patient Outcome.

Authors:  Susana Vacas; Maxime Cannesson
Journal:  J Cardiothorac Vasc Anesth       Date:  2019-08       Impact factor: 2.628

Review 7.  Neurophysiological assessment of brain dysfunction in critically ill patients: an update.

Authors:  Eric Azabou; Catherine Fischer; Jean Michel Guerit; Djillali Annane; François Mauguiere; Fréderic Lofaso; Tarek Sharshar
Journal:  Neurol Sci       Date:  2017-01-21       Impact factor: 3.307

8.  Propofol and non-propofol based sedation for outpatient colonoscopy-prospective comparison of depth of sedation using an EEG based SEDLine monitor.

Authors:  Basavana Goudra; Preet Mohinder Singh; Gowri Gouda; Anuradha Borle; Augustus Carlin; Avantika Yadwad
Journal:  J Clin Monit Comput       Date:  2015-09-12       Impact factor: 2.502

9.  Burst-suppression ratio underestimates absolute duration of electroencephalogram suppression compared with visual analysis of intraoperative electroencephalogram.

Authors:  W G Muhlhofer; R Zak; T Kamal; B Rizvi; L P Sands; M Yuan; X Zhang; J M Leung
Journal:  Br J Anaesth       Date:  2017-05-01       Impact factor: 9.166

10.  Offline comparison of processed electroencephalogram monitors for anaesthetic-induced electroencephalogram changes in older adults.

Authors:  Sarah L Eagleman; Caitlin M Drover; Xi Li; M Bruce MacIver; David R Drover
Journal:  Br J Anaesth       Date:  2021-02-25       Impact factor: 9.166

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.