Literature DB >> 16631057

Anterior chamber measurements using Pentacam rotating Scheimpflug camera.

Tanja M Rabsilber1, Ramin Khoramnia, Gerd U Auffarth.   

Abstract

PURPOSE: To investigate the mean values and standard deviations according to age, reliability, and correlation between different parameters of anterior chamber measurements using the Pentacam rotating Scheimpflug camera.
SETTING: Heidelberg IOL and Refractive Surgery Research Group, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.
METHODS: This prospective clinical study comprised 76 healthy volunteers (mean age 46.6 years +/- 16.8 [SD]). Three consecutive measurements were made of only 1 eye and anterior chamber depth (ACD), mean and minimum anterior chamber angle (ACA), and anterior chamber volume (ACV) were evaluated.
RESULTS: Mean ACD was 2.93 +/- 0.36 mm, mean ACA was 34.81 +/- 5.05 degrees, minimum ACA was 29.99 +/- 5.53 degrees, and mean ACV was 160.3 +/- 36.81 mm3. Increasing age was associated with reduced ACD and ACV; however, mean and minimum ACAs were lowest in patients aged 40 to 59 years. Excellent correlation was found between ACD and ACV (R = 0.92). Anterior chamber depth and mean ACA correlated only moderately (R = 0.65). The correlation coefficient between ACD and minimum ACA was smaller (R = 0.58). There was no correlation between ACV and ACA (R = 0.37). Minor standard deviations were noted (ACD 0.02 +/- 0.02 mm, mean ACA 1.12 +/- 0.94 degrees, minimum ACA 2.04 +/- 2.67 degrees, and ACV 2.48 +/- 1.65 mm3).
CONCLUSIONS: Using the Pentacam, it was possible to examine different parameters of the anterior chamber within a short period and with good reliability. The evaluation of the ACA in different positions can help to classify the potential risk for angle-closure glaucoma.

Entities:  

Mesh:

Year:  2006        PMID: 16631057     DOI: 10.1016/j.jcrs.2005.12.103

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  50 in total

1.  Effects of primary selective laser trabeculoplasty on anterior segment parameters.

Authors:  Suzan Guven Yilmaz; Melis Palamar; Emil Yusifov; Halil Ates; Sait Egrilmez; Ayse Yagci
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

2.  Alteration of anterior chamber in 81 glaucomatous eyes using Pentacam Scheimpflug system.

Authors:  Xuan Zou; Xuan-Chu Duan; Qian Zhong
Journal:  Int J Ophthalmol       Date:  2010-12-18       Impact factor: 1.779

3.  Anterior chamber depth in normal subjects by rotating scheimpflug imaging.

Authors:  Matthew T Feng; Michael W Belin; Renato Ambrósio; Satinder P S Grewal; Wang Yan; Mohamed S Shaheen; Charles McGhee; Naoyuki Maeda; Tobias H Neuhann; H Burkhard Dick; Saleh A Alageel; Andreas Steinmueller
Journal:  Saudi J Ophthalmol       Date:  2011-04-30

4.  Assessment of the anterior chamber parameters after laser iridotomy in primary angle close suspect using Pentacam and gonioscopy.

Authors:  Alireza Esmaeili; Behzad Barazandeh; Sina Ahmadi; Alireza Haghi; Seyed Mahdi Ahmadi Hosseini; Fereshteh Abolbashari
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

5.  Quantitative Scheimpflug camera study of the lens density in healthy Turkish population.

Authors:  Taner Kar; Yakup Aksoy; Yıldıray Yıldırım; Abdullah Kaya; Ali Ayata; Melih Hamdi Ünal
Journal:  Int Ophthalmol       Date:  2016-02-25       Impact factor: 2.031

6.  [Scheimpflug and topography systems in ophthalmologic diagnostics].

Authors:  G U Auffarth; A F M Borkenstein; A Ehmer; A Mannsfeld; T M Rabsilber; M P Holzer
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

7.  [Influence of corneal pachymetric changes on functional results after cataract surgery].

Authors:  F N Auerbach; M P Holzer; G U Auffarth; R Khoramnia; B C Thomas; D Saure; T M Rabsilber
Journal:  Ophthalmologe       Date:  2015-10       Impact factor: 1.059

8.  Corneal sublayer thickness in patients with pseudoexfoliation syndrome evaluated by anterior segment optical coherence tomography.

Authors:  Abdulhakim Tekce; Mehmet Gulmez
Journal:  Int Ophthalmol       Date:  2019-11-07       Impact factor: 2.031

9.  [Scheimpflug photography of acute angle closure].

Authors:  J D Unterlauft; Y Yafai; P Wiedemann
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

10.  Anterior segment parameters in Indian young adults using the Pentacam.

Authors:  Seyed Mahdi Ahmadi Hosseini; Fereshteh Abolbashari; Norhani Mohidin
Journal:  Int Ophthalmol       Date:  2013-03-01       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.