The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening : a comparison based on a new torque value index: the fixation index.

R Placzek1, M Ruffer, G Deuretzbacher, E Heijens, A L Meiss.   

Abstract

INTRODUCTION: Lengthening procedures are often complicated by loosening of pins. It has been reported that coating with hydroxyapatite improves fixation and reduces the rate of pin-track infection.
MATERIALS AND METHODS: We compared 47 hydroxyapatite-coated Schanz screws (HA screws) in 12 monolateral fixators mounted at the University Hospital Hamburg-Eppendorf with 45 standard stainless steel screws in 9 monolateral fixators mounted at the St Josefs-Hospital Wiesbaden by measuring the insertion and extraction torque values. The average implantation period was 7 months for the hydroxyapatite-coated screws and 5.4 months for the uncoated screws. We established the quotient of the maximum extraction torque over insertion torque which shows the change in the fixation strength with respect to time, the fixation index. It eliminates the influence of the varying pin-bone contact.
RESULTS: There was no significant difference in the rate of infection. In the Schanz screws without signs of infection the index was 1.92 for the HA screws and 0.76 for the stainless steel screws (P = 0.0002) giving evidence of the improvement of the fixation by the coating.
CONCLUSION: HA coating resulted in improved fixation of Schanz screws in bone and may be useful in prolonged external fixation of the lower leg. The fixation index proved to be a simple tool for the evaluation of the fixation strength of Schanz screws.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16628428     DOI: 10.1007/s00402-006-0142-5

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  8 in total

1.  Outcome evaluation of new calcium titanate schanz-screws for external fixators. First clinical results and cadaver studies.

Authors:  Martin Gathen; Milena Maria Ploeger; Max Jaenisch; Sebastian Koob; Davide Cucchi; Adnan Kasapovic; Thomas Randau; Richard Placzek
Journal:  J Mater Sci Mater Med       Date:  2019-11-08       Impact factor: 3.896

2.  Augmentation of implant fixation in osteoporotic bone.

Authors:  Clifford B Jones
Journal:  Curr Osteoporos Rep       Date:  2012-12       Impact factor: 5.096

3.  Pulsed laser deposition of hydroxyapatite on titanium substrate with titania interlayer.

Authors:  P Rajesh; C V Muraleedharan; Manoj Komath; Harikrishna Varma
Journal:  J Mater Sci Mater Med       Date:  2011-01-14       Impact factor: 3.896

4.  Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.

Authors:  Zi-Li Wang; Rong-Zhen He; Bin Tu; Xu Cao; Jin-Shen He; Han-Song Xia; Chi Liang; Min Zou; Song Wu; Zhen-Jun Wu; Kun Xiong
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

5.  External fixator pin placement during initial management of tibial plateau fractures: are there parameters to minimize pin-plate overlap?

Authors:  Douglas R Haase; Lucas R Haase; Tyler J Moon; Marcus Trotter; Joshua K Napora; Brent T Wise
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-08-18

6.  Improved bonding of partially osteomyelitic bone to titanium pins owing to biomimetic coating of apatite.

Authors:  Hirotaka Mutsuzaki; Yu Sogo; Ayako Oyane; Atsuo Ito
Journal:  Int J Mol Sci       Date:  2013-12-13       Impact factor: 5.923

Review 7.  Biomechanical analysis of four external fixation pin insertion techniques.

Authors:  Dillon Arango; Nathan Tiedeken; Benjamin Clippinger; Solomon Praveen Samuel; Vilas Saldanha; Gene Shaffer
Journal:  Orthop Rev (Pavia)       Date:  2017-10-03

8.  [External fixation for treatment of peripartum pubic symphysis separation : Clinical case and discussion].

Authors:  M Müller; F Greve; M Zyskowski; M Wurm; P Biberthaler; C Kirchhoff
Journal:  Unfallchirurg       Date:  2020-12-17       Impact factor: 1.000