Literature DB >> 16624318

Evaluation of a 3D object registration method for analysis of humeral kinematics.

Evgenij Bobrowitsch1, Carl Imhauser, Heiko Graichen, Lutz Dürselen.   

Abstract

In 3D image-based studies of joint kinematics, 3D registration methods should be automatic, insensitive to segmentation inconsistencies and use coordinate systems that have clinically relevant orientations and locations because this is important for analyzing rotation angles and translation directions. We developed and evaluated a registration method, which is based on the cylindrical geometry of the humerus shaft and an analysis of the inertia moments of the humerus head, in order to consistently and automatically orient the humerus coordinate system according to its anatomy. Registration techniques must be thoroughly evaluated. In this study we used a well-detectable marker as reference, from which coordinate system determination errors of a 3D object could be measured. This allowed us to quantify by means of unique error analysis the translational and rotational errors in terms of how much and about/along which humeral axis errors occurred. The evaluation experiments were performed using virtual rotations of 3D humeral binary image, a humerus model and a 3D image of a volunteer's shoulder. They indicated that the humeral coordinate system determination errors primarily originated from segmentation inconsistencies, which influenced mostly the humeral transverse axes orientation. The error analysis revealed that the developed registration method reduced the effect of manual segmentation inconsistencies on the orientation of the humeral transverse axes up to 37%, in comparison to the commonly used inertia registration.

Entities:  

Mesh:

Year:  2006        PMID: 16624318     DOI: 10.1016/j.jbiomech.2006.02.016

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Digital stereophotogrammetry based on circular markers and zooming cameras: evaluation of a method for 3D analysis of small motions in orthopaedic research.

Authors:  Evgenij Bobrowitsch; Christof Hurschler; Gavin Olender; Christian Plaass; Hazibullah Waizy; Heino Arnold; Christina Stukenborg-Colsman
Journal:  Biomed Eng Online       Date:  2011-02-01       Impact factor: 2.819

2.  Biomechanical in vitro - stability testing on human specimens of a locking plate system against conventional screw fixation of a proximal first metatarsal lateral displacement osteotomy.

Authors:  Heino Arnold; Christina Stukenborg-Colsman; Christof Hurschler; Frank Seehaus; Evgenij Bobrowitsch; Hazibullah Waizy
Journal:  Open Orthop J       Date:  2012-04-04

3.  Proximal humeral coordinate systems can predict humerothoracic and glenohumeral kinematics of a full bone system.

Authors:  Hema J Sulkar; Jared L Zitnay; Klevis Aliaj; Heath B Henninger
Journal:  Gait Posture       Date:  2021-09-20       Impact factor: 2.746

4.  A survey of human shoulder functional kinematic representations.

Authors:  Rakesh Krishnan; Niclas Björsell; Elena M Gutierrez-Farewik; Christian Smith
Journal:  Med Biol Eng Comput       Date:  2018-10-26       Impact factor: 2.602

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.