Literature DB >> 16622873

Evaluation of FDA licensed HIV assays using plasma from Cameroonian blood donors.

Sherwin Lee1, Jinjie Hu, Shixing Tang, Owen Wood, Kori Francis, Ana Machuca, Maria Rios, Sylvester Daniel, Christopher Vockley, Bih Awazi, Leopold Zekeng, Indira Hewlett.   

Abstract

Several diagnostic assays for the detection of HIV infection have been approved and licensed by the FDA for blood donor screening. However, the performance of these assays is unknown when testing genetically divergent blood specimens. To evaluate the performance of these assays with diverse HIV strains, we chose to study specimens collected from blood donors in Cameroon where genetic diversity and recombinant variants are prevalent. In this study, we tested 240 human plasma specimens collected from two blood centers in Cameroon. These samples were screened initially in Cameroon for antibody to HIV using a rapid assay. We also performed sequencing to determine subtype. Our evaluation has demonstrated that HIV infection in most HIV plasma samples could be detected by most of the US FDA licensed diagnostic assays. With the exception of a few specimens, HIV-1 p24 antigen was not detected in any of the samples. In addition, some nucleic acid tests (NAT) assays were not able to detect a few serologic reactive samples and all new variants including some CRF02_AG variants.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16622873     DOI: 10.1002/jmv.20602

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  2 in total

1.  Transfusion safety in francophone African countries: an analysis of strategies for the medical selection of blood donors.

Authors:  Claude Tayou Tagny; Maxime Diané Kouao; Hamane Touré; Jalel Gargouri; Ahamada Said Fazul; Siaka Ouattara; Ludovic Anani; Habiba Othmani; Lochina Feteke; Honorine Dahourou; Guy Olivier Mbensa; Simplice Molé; Yacouba Nébié; Madeleine Mbangue; Michel Toukam; Mahommed Ould Boulahi; Lalatiana Valisoa Andriambelo; Olivat Rakoto; Mounirou Baby; Rakia Yahaya; Amelia Bokilo; Florent Senyana; Dora Mbanya; Caroline Shiboski; Edward L Murphy; Jean Jacques Lefrère
Journal:  Transfusion       Date:  2011-10-20       Impact factor: 3.157

2.  Field evaluation of Calypte's AWARE blood serum plasma (BSP) and oral mucosal transudate (OMT) rapid tests for detecting antibodies to HIV-1 and 2 in plasma and oral fluid.

Authors:  George A Alemnji; Gisele A Ngulefac; Peter M Ndumbe; Tazoacha Asonganyi
Journal:  Open AIDS J       Date:  2009-03-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.