Literature DB >> 16608058

Morphological segmentation and partial volume analysis for volumetry of solid pulmonary lesions in thoracic CT scans.

Jan-Martin Kuhnigk1, Volker Dicken, Lars Bornemann, Annemarie Bakai, Dag Wormanns, Stefan Krass, Heinz-Otto Peitgen.   

Abstract

Volumetric growth assessment of pulmonary lesions is crucial to both lung cancer screening and oncological therapy monitoring. While several methods for small pulmonary nodules have previously been presented, the segmentation of larger tumors that appear frequently in oncological patients and are more likely to be complexly interconnected with lung morphology has not yet received much attention. We present a fast, automated segmentation method that is based on morphological processing and is suitable for both small and large lesions. In addition, the proposed approach addresses clinical challenges to volume assessment such as variations in imaging protocol or inspiration state by introducing a method of segmentation-based partial volume analysis (SPVA) that follows on the segmentation procedure. Accuracy and reproducibility studies were performed to evaluate the new algorithms. In vivo interobserver and interscan studies on low-dose data from eight clinical metastasis patients revealed that clinically significant volume change can be detected reliably and with negligible computation time by the presented methods. In addition, phantom studies were conducted. Based on the segmentation performed with the proposed method, the performance of the SPVA volumetry method was compared with the conventional technique on a phantom that was scanned with different dosages and reconstructed with varying parameters. Both systematic and absolute errors were shown to be reduced substantially by the SPVA method. The method was especially successful in accounting for slice thickness and reconstruction kernel variations, where the median error was more than halved in comparison to the conventional approach.

Entities:  

Mesh:

Year:  2006        PMID: 16608058     DOI: 10.1109/TMI.2006.871547

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  51 in total

1.  Comparative study with new accuracy metrics for target volume contouring in PET image guided radiation therapy.

Authors:  Tony Shepherd; Mika Teras; Reinhard R Beichel; Ronald Boellaard; Michel Bruynooghe; Volker Dicken; Mark J Gooding; Peter J Julyan; John A Lee; Sébastien Lefèvre; Michael Mix; Valery Naranjo; Xiaodong Wu; Habib Zaidi; Ziming Zeng; Heikki Minn
Journal:  IEEE Trans Med Imaging       Date:  2012-06-04       Impact factor: 10.048

2.  Shape "break-and-repair" strategy and its application to automated medical image segmentation.

Authors:  Jiantao Pu; David S Paik; Xin Meng; Justus E Roos; Geoffrey D Rubin
Journal:  IEEE Trans Vis Comput Graph       Date:  2011-01       Impact factor: 4.579

3.  A Combination of Shape and Texture Features for Classification of Pulmonary Nodules in Lung CT Images.

Authors:  Ashis Kumar Dhara; Sudipta Mukhopadhyay; Anirvan Dutta; Mandeep Garg; Niranjan Khandelwal
Journal:  J Digit Imaging       Date:  2016-08       Impact factor: 4.056

4.  Special computer-aided computed tomography (CT) volume measurement and comparison method for pulmonary tuberculosis (TB).

Authors:  Jingming Liu; Zhaogang Sun; Ruming Xie; Mengqiu Gao; Chuanyou Li
Journal:  Int J Clin Exp Med       Date:  2015-09-15

5.  Automated volumetry of pulmonary nodules on multidetector CT: influence of slice thickness, reconstruction algorithm and tube current. Preliminary results.

Authors:  A R Larici; M L Storto; M Torge; M Mereu; F Molinari; F Maggi; L Bonomo
Journal:  Radiol Med       Date:  2008-02-25       Impact factor: 3.469

6.  Automated measurement of lymph nodes: a phantom study.

Authors:  Sebastian Keil; Cedric Plumhans; Florian F Behrendt; Sven Stanzel; Michael Suehling; Georg Mühlenbruch; Andreas H Mahnken; Rolf W Günther; Marco Das
Journal:  Eur Radiol       Date:  2008-12-24       Impact factor: 5.315

Review 7.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

8.  Accuracy of MRI volume measurements of breast lesions: comparison between automated, semiautomated and manual assessment.

Authors:  Marga B Rominger; Daphne Fournell; Beenarose Thanka Nadar; Sarah N M Behrens; Jens H Figiel; Boris Keil; Johannes T Heverhagen
Journal:  Eur Radiol       Date:  2009-01-22       Impact factor: 5.315

9.  3D shape analysis to reduce false positives for lung nodule detection systems.

Authors:  Antonio Oseas de Carvalho Filho; Aristófanes Corrêa Silva; Anselmo Cardoso de Paiva; Rodolfo Acatauassú Nunes; Marcelo Gattass
Journal:  Med Biol Eng Comput       Date:  2016-10-17       Impact factor: 2.602

10.  Computed tomography assessment of response to therapy: tumor volume change measurement, truth data, and error.

Authors:  Michael F McNitt-Gray; Luc M Bidaut; Samuel G Armato; Charles R Meyer; Marios A Gavrielides; Charles Fenimore; Geoffrey McLennan; Nicholas Petrick; Binsheng Zhao; Anthony P Reeves; Reinhard Beichel; Hyun-Jung Grace Kim; Lisa Kinnard
Journal:  Transl Oncol       Date:  2009-12       Impact factor: 4.243

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.