Literature DB >> 16600616

Transapical approach for sutureless stent-fixed aortic valve implantation: experimental results.

Thomas Walther1, Todd Dewey, Gerhard Wimmer-Greinecker, Mirko Doss, Rainer Hambrecht, Gerhard Schuler, Friedrich W Mohr, Michael Mack.   

Abstract

OBJECTIVE: Percutaneous aortic valve implantation has been performed in patients with severe aortic stenosis judged as nonsurgical candidates. We evaluated a facilitated transapical antegrade approach for potential use in surgical high-risk patients.
METHODS: A pericardial xenograft fixed within a 23-mm stent (Cribier-Edwards aortic prosthesis, Edwards Inc., Irvine, CA, USA) was implanted using a transapical approach in fifteen 35-45 kg pigs. A limited or a full sternotomy was used to transapically introduce a crimped valve through a 24-F sheath. Deployments were performed on the beating heart either with ventricular unloading using femoro-femoral cardiopulmonary bypass (CPB) or rapid ventricular pacing (RVP), all under fluoroscopic and echocardiographic visualization.
RESULTS: All valves were successfully deployed at the target site with acceptable visualization of the noncalcified annulus. Valve migration occurred in six procedures (three distal and three retrograde) secondary to inadequate reduction of ventricular output, unfavorable annular anatomy, excessive crimping of the valve, and dislodgement by the delivery balloon. Exact positioning of the valve into the target area was confirmed by autopsy at the end of the procedures. Paravalvular leak was noted in five implants.
CONCLUSIONS: The transapical approach provides a safe, accurate, and effective route for facilitated antegrade delivery of a stent-fixed valve. Advanced stent design will lead to better stability of the implant and may minimize the risk of paravalvular leakage in future. Identifying the appropriate population for human feasibility trials remains a challenge.

Entities:  

Mesh:

Year:  2006        PMID: 16600616     DOI: 10.1016/j.ejcts.2006.01.062

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  6 in total

1.  Transapical aortic valve replacement under real-time magnetic resonance imaging guidance: experimental results with balloon-expandable and self-expanding stents.

Authors:  Keith A Horvath; Dumitru Mazilu; Ozgur Kocaturk; Ming Li
Journal:  Eur J Cardiothorac Surg       Date:  2010-10-22       Impact factor: 4.191

2.  Minimally invasive primary aortic valve surgery: the OLV Aalst experience.

Authors:  Johan van der Merwe; Filip Casselman; Bernard Stockman; Frank Van Praet; Roel Beelen; Lieven Maene; Yvette Vermeulen; Ivan Degrieck
Journal:  Ann Cardiothorac Surg       Date:  2015-03

3.  Quantification of biomechanical interaction of transcatheter aortic valve stent deployed in porcine and ovine hearts.

Authors:  Joseph Mummert; Eric Sirois; Wei Sun
Journal:  Ann Biomed Eng       Date:  2012-11-17       Impact factor: 3.934

4.  Quantification of structural compliance of aged human and porcine aortic root tissues.

Authors:  Kewei Li; Qian Wang; Thuy Pham; Wei Sun
Journal:  J Biomed Mater Res A       Date:  2013-09-02       Impact factor: 4.396

Review 5.  Experimental and computational models for tissue-engineered heart valves: a narrative review.

Authors:  Ge Yan; Yuqi Liu; Minghui Xie; Jiawei Shi; Weihua Qiao; Nianguo Dong
Journal:  Biomater Transl       Date:  2021-12-28

6.  Minimally invasive cardiac surgery: transapical aortic valve replacement.

Authors:  Ming Li; Dumitru Mazilu; Keith A Horvath
Journal:  Minim Invasive Surg       Date:  2012-10-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.