Literature DB >> 16598478

A comparison of the accuracy of two minimally invasive breast biopsy methods: a systematic literature review and meta-analysis.

Kyle Fahrbach1, Isabella Sledge, Catherine Cella, Heather Linz, Susan D Ross.   

Abstract

OBJECTIVE: The primary objective was to quantify and compare the accuracy and failure rates of directional vacuum assisted biopsy (DVAB) and core needle biopsy (CNB) when used under stereotactic (ST) guidance to biopsy suspicious breast lesions identified with screening mammography.
METHODS: We performed a systematic review of the literature published from January 1996 to July 2004, reporting all-comers populations in Western-style health care systems (i.e., North America, Europe, Australia or New Zealand), referred after screening mammography for breast biopsy using DVAB or CNB under ST guidance. Meta-analyses were conducted for DVAB and CNB, using open surgical biopsy and/or long-term clinical and/or mammogram follow-up as the diagnostic reference standard. The main outcomes of interest were those of greatest clinical relevance, i.e., miss rates and underestimation rates for malignancy. Also, technical failure rate and non-diagnostic rate were assessed for each biopsy method.
RESULTS: Thirty-five studies qualified for the review. There were 12 studies with a DVAB group (n=5,119 patients), and 25 studies with a CNB group (n=6,236). There were no studies including both a DVAB and a CNB group, thus precluding any direct, within-study comparisons of accuracy. Overall agreement rate between DVAB and the reference standard was 97.3%, and between CNB and the reference standard, 93.5%. The frequency of technical failures with CNB was slightly higher than DVAB (5.7 vs. 1.5%), as was the frequency of non-diagnostic samples (2.1 vs. 0%). Of the non-diagnostic CNB samples, 23% were subsequently found to be malignant on reference standard. In multivariate analyses using four covariates (procedure type, geographic location, reference standard, and patient position), there were no significant predictors of agreement rates, but some variables were significant predictors of miss rates. For benign to malignant upgrades, study location was a significant predictor, with more upgrades in non-NA locations. For atypia to malignant upgrades, the type of procedure was a significant predictor, with more underestimations in CNB studies.
CONCLUSION: The best available evidence suggests that, in screening populations referred for minimally invasive breast biopsy biopsy requiring ST guidance, DVAB may provide lower miss and underestimation rates for clinically relevant diagnoses than does CNB.

Entities:  

Mesh:

Year:  2006        PMID: 16598478     DOI: 10.1007/s00404-005-0106-y

Source DB:  PubMed          Journal:  Arch Gynecol Obstet        ISSN: 0932-0067            Impact factor:   2.344


  8 in total

1.  B3 Lesions: Radiological Assessment and Multi-Disciplinary Aspects.

Authors:  Sylvia H Heywang-Köbrunner; Jörg Nährig; Astrid Hacker; Stefan Sedlacek; Heinz Höfler
Journal:  Breast Care (Basel)       Date:  2010-08-23       Impact factor: 2.860

2.  Diagnostic underestimation of atypical ductal hyperplasia and ductal carcinoma in situ at percutaneous core needle and vacuum-assisted biopsies of the breast in a Brazilian reference institution.

Authors:  Gustavo Machado Badan; Decio Roveda Júnior; Sebastião Piato; Eduardo de Faria Castro Fleury; Mário Sérgio Dantas Campos; Carlos Alberto Ferreira Pecci; Felipe Augusto Trocoli Ferreira; Camila D'Ávila
Journal:  Radiol Bras       Date:  2016 Jan-Feb

3.  Role of one-pass breast lesion excision system in complete excision of high-risk breast lesions with atypia expressed as clusters of microcalcifications.

Authors:  Alexandra Christou; Vassilis Koutoulidis; Dimitra Koulocheri; Evangelia Panourgias; Afrodite Nonni; Constantinos G Zografos; George C Zografos
Journal:  Eur Radiol       Date:  2019-01-07       Impact factor: 5.315

4.  Stereotactic breast biopsy efficiency: Does a pre-biopsy grid image help?

Authors:  Victoria L Mango; Donna D'Alessio; Elizabeth A Morris; Richard Ha; Blanca Bernard-Davila; Maxine S Jochelson
Journal:  Clin Imaging       Date:  2018-10-06       Impact factor: 1.605

5.  Value of stereotactic 11-gauge vacuum-assisted breast biopsy in non-palpable suspicious calcifications: an eight-year single institution experience with 587 patients.

Authors:  Shiping Li; Feilin Qu; Yinlong Yang; Lei Wang; Juping Shen; Zhiming Shao
Journal:  Gland Surg       Date:  2020-10

6.  When Is Sentinel Node Biopsy Indicated in High-Risk Ductal Carcinoma in situ? Four Hundred Sixty-Eight Cases from Three Institutions.

Authors:  Tomás Cortadellas; Paula Argacha; Juan Acosta; Judith Jurado; Ricardo Peiró; Margarita Gomez; Xavier Gonzalez-Farré; Milagros Martinez; Miguel Luna; Vicente Peg; Antonio Gil-Moreno; Manel Xiberta
Journal:  Breast Care (Basel)       Date:  2021-03-30       Impact factor: 2.860

7.  A comparison of diagnostic performance of vacuum-assisted biopsy and core needle biopsy for breast microcalcification: a systematic review and meta-analysis.

Authors:  Xu Chen Huang; Xu Hua Hu; Xiao Ran Wang; Chao Xi Zhou; Fei Fei Wang; Shan Yang; Gui Ying Wang
Journal:  Ir J Med Sci       Date:  2018-03-16       Impact factor: 1.568

8.  Sentinel lymph node biopsy can be omitted in DCIS patients treated with breast conserving therapy.

Authors:  L M van Roozendaal; B Goorts; M Klinkert; K B M I Keymeulen; B De Vries; L J A Strobbe; C A P Wauters; Y E van Riet; E Degreef; E J T Rutgers; J Wesseling; M L Smidt
Journal:  Breast Cancer Res Treat       Date:  2016-04-15       Impact factor: 4.872

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.