Literature DB >> 16584153

Wet granulation in rotary processor and fluid bed: comparison of granule and tablet properties.

Jakob Kristensen1, Vibeke Wallaert Hansen.   

Abstract

The aim of the present study was to investigate and compare granule and tablet properties of granules prepared by wet granulation in a rotary processor or a conventional fluid bed. For this purpose the working range of selected process variables was determined and a factorial study with 3 factors (equipment type, filler type, and liquid addition rate) and 1 covariate (fluidizing air flow rate) was performed. Two grades of calcium carbonate with different size and shape characteristics were applied, and the liquid addition and fluidizing air flow rates were investigated in the widest possible range. Dry mixtures of microcrystalline cellulose, polyvinyl povidone, calcium carbonate, and riboflavin, in a 10:5:84:1 ratio, were granulated in both types of equipment. The granulation end point was determined manually in the fluid bed and by torque measurements in the rotary processor. The filler type had a more pronounced effect on granular properties in the fluid bed, but the rotary processor showed a higher dependency on the investigated process variables. The rotary processor gave rise to more dense granules with better flow properties, but the fluid bed granules had slightly better compressional properties. Furthermore, the distribution of a low-dose drug was found to be more homogeneous in the rotary processor granules and tablets. Generally, wet granulation in a rotary processor was found to be a good alternative to conventional fluid bed granulation, especially when cohesive powders with poor flow properties or formulations with low drug content are to be granulated by a fluidizing air technique.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16584153      PMCID: PMC2750501          DOI: 10.1208/pt070122

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  5 in total

1.  Performance optimization of spectroscopic process analyzers.

Authors:  Hans F M Boelens; Wim Th Kok; Onno E De Noord; Age K Smilde
Journal:  Anal Chem       Date:  2004-05-01       Impact factor: 6.986

2.  Near-infrared spectroscopy for the determination of testosterone in thin-film composites.

Authors:  William Fountain; Karen Dumstorf; Amanda E Lowell; Robert A Lodder; Russell J Mumper
Journal:  J Pharm Biomed Anal       Date:  2003-09-19       Impact factor: 3.935

3.  Phospholipid immobilization on solid surfaces.

Authors:  S Ong; S J Cai; C Bernal; D Rhee; X Qiu; C Pidgeon
Journal:  Anal Chem       Date:  1994-03-15       Impact factor: 6.986

4.  Derivatization procedure and HPLC determination of 2-ethoxyethanol in cosmetic samples.

Authors:  E Mariani; C Villa; C Neuhoff; S Dorato
Journal:  Int J Cosmet Sci       Date:  1999-06       Impact factor: 2.970

5.  Near-infrared spectrometry for the quantification of dermal absorption of econazole nitrate and 4-cyanophenol.

Authors:  Joseph Medendorp; Jhansi Yedluri; Dana C Hammell; Tao Ji; Robert A Lodder; Audra L Stinchcomb
Journal:  Pharm Res       Date:  2006-03-29       Impact factor: 4.200

  5 in total
  3 in total

1.  The manufacture of low-dose oral solid dosage form to support early clinical studies using an automated micro-filing system.

Authors:  Mingda Bi; Changquan Calvin Sun; Francisco Alvarez; Fernando Alvarez-Nunez
Journal:  AAPS PharmSciTech       Date:  2010-12-23       Impact factor: 3.246

2.  Preparation and in vitro evaluation of polystyrene-coated diltiazem-resin complex by oil-in-water emulsion solvent evaporation method.

Authors:  Arindam Halder; Biswanath Sa
Journal:  AAPS PharmSciTech       Date:  2006-05-26       Impact factor: 3.246

3.  Investigation on side-spray fluidized bed granulation with swirling airflow.

Authors:  Poh Mun Wong; Lai Wah Chan; Paul Wan Sia Heng
Journal:  AAPS PharmSciTech       Date:  2012-12-21       Impact factor: 3.246

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.